3. Unscrew the spoke magnet
from the plastic piece. Place
the spoke in the groove of
the plastic piece and tighten
slightly. The magnet can face
away from the GSC 10 if there
is not enough room between
the sensor arm and the spoke.
The magnet must be aligned
with the sensor arm indication
line.
4. Loosen the screw on the
sensor arm and move it to
within 5 mm of the spoke
magnet. You can also
tilt the GSC 10 closer to
either magnet for improved
alignment.
5. Press the
Reset
button on
the GSC 10. The LED turns
red, then green. Pedal to test
the sensor alignment. The