Serial Interface Specifications
70
Apollo GX50/60/65 Installation Manual
“Z”
D
ATA
F
ORMAT
The format of the fuel/air data computer input is as follows, which conforms to the Shadin
“Z” format serial message. Definition of the input message data that the GX50/60/65 uses is
included in Table 13.
Baud rate: ..........................................9600
Data bits: ...........................................8
Stop bits: ...........................................1
Parity: ................................................none
Expected input rate: ..........................approx. 1 second
Message length: ................................variable (512 character max.)
The serial input message string is expected in the following format.
<STX><message><message> ... <message><chksum><ETX>
<STX> ...............................................ASCII “start of text” character (STX = 02h)
<message> .........................................starts with an ASCII “Z”, then an ID character,
followed by the message data, a carriage return (CR
= 0Dh), and a line feed (LF = 0Ah) See the
following table.
<checksum>.......................................the message checksum, same format as message
<ETX> ...............................................ASCII “end of text” character (ETX = 03h)
Example Fuel / Airdata Input Data
<STX>SA223
223 knots indicated air speed
SB230
230 knots true air speed
SC101
0.101
mach
SD+3200
32,000 feet pressure altitude
SE+3312
33,120 feet density altitude
SF+05
+5°C
outside
air
temp
SG-03
-3°C
true
air
temp
SH010
wind direction at 10° (relative to true north)
SI015
wind speed at 15 knots
SJ+03
+3° / second right turn
SK-050
-50 feet / second vertical air speed
SL359
359° heading (relative to true north)
SM0123
12.3 gallons / hour - right engine fuel flow
SN0300
30.0 gallons used - right engine
SO0131
13.1 gallons / hour - left engine fuel flow
SP0310
31.0 gallons used - left engine
SQ000
no
errors
SR01227
122.7 gallons remaining
S*123
Checksum (example only, not actual)
<ETX>
end
of
message
string
Figure 20 Fuel / Airdata Data Input (S Format)
Содержание APOLLO GX60
Страница 4: ...NOTES ...
Страница 8: ...Table of Contents iv Apollo GX50 60 65 Installation Manual NOTES ...
Страница 10: ...Introduction 2 Apollo GX50 60 65 Installation Manual Figure 1 GX50 Front Panel Figure 2 GX60 65 Front Panel ...
Страница 21: ...Installation Apollo GX50 60 65 Installation Manual 13 Figure 4 Mounting Frame Assembly Figure 5 Cable Routing ...
Страница 26: ...Installation 18 Apollo GX50 60 65 Installation Manual Figure 8 GX50 60 65 Power and Avionics Connections ...
Страница 30: ...Installation 22 Apollo GX50 60 65 Installation Manual Figure 12 RS 232 Serial Connections ...
Страница 31: ...Installation Apollo GX50 60 65 Installation Manual 23 Figure 13 GX60 65 Comm Wiring Diagram ...
Страница 32: ...Installation 24 Apollo GX50 60 65 Installation Manual Figure 14 GX60 65 Typical Audio Panel Connections ...
Страница 40: ...Installation 32 Apollo GX50 60 65 Installation Manual NOTES ...
Страница 50: ...Limitations 42 Apollo GX50 60 65 Installation Manual NOTES ...
Страница 54: ...Periodic Maintenance 46 Apollo GX50 60 65 Installation Manual NOTES ...
Страница 82: ...Serial Interface Specifications 74 Apollo GX50 60 65 Installation Manual NOTES ...
Страница 84: ...Full Stack Drawing 76 Apollo GX50 60 65 Installation Manual ...
Страница 85: ......
Страница 86: ......