Post-Installation Configuration & Checkout
Apollo CNX80 Installation Manual
560-0982-00 Rev D
3-5
3.2.1.3 Resolver Interface Selection and Calibration
The Resolver Interface function lets you to select whether or not a resolver is installed, and allows an
installed resolver to be calibrated. While on the Ground Maintenance SETUP menu page, press the
RESOLVER
line select key. Then press the top line select key to toggle between INSTALLED (for
installations with a resolver) or NOT INSTALLED (for installations without a resolver). The resolver
interface setup page is shown in Figure 3-4.
Figure 3-4 - Resolver Interface Setup Page
When a resolver is installed, calibrate it as follows:
1.
Press the
CAL
line select key. The calibration page shown in Figure 3-5 will then be displayed. If
the
CAL
line select key is pressed when the resolver is set to NOT INSTALLED, it will
automatically be changed to INSTALLED.
2.
Press the
10/30
line select key to toggle between 10 and 30 degrees for the calibration increment.
NOTE
An increment of 30 degrees should be acceptable for most installations. However, if
resolver errors of more than two degrees are present following the calibration, the
calibration procedure should be repeated using the 10 degree increment (this will create a
more accurate calibration table but will require more time to perform the calibration).
3.
Follow the instructions on the display for calibrating the resolver. If the CNX80 will not accept the
calibration or advances to the next prompt when the
MENU/ENTER
key is pressed, there may be
a problem with the resolver interface.
NOTE
The accuracy of the system is dependent on this calibration. Do not rush this step.
4.
After successfully calibrating the resolver a green CALIBRATION PASSED message will be
displayed. After this message appears, rotate the resolver and ensure that the CURRENT
RESOLVER VALUE being displayed is within two degrees of the actual resolver setting.
Содержание Apollo CNX80
Страница 1: ...Apollo CNX80 Installation Manual September 2003 560 0982 00 Rev D...
Страница 10: ...Table of Contents viii 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Страница 30: ...General Information 1 20 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Страница 41: ...Installation Procedures Apollo CNX80 Installation Manual 560 0982 00 Rev D 2 11 Figure 2 3 CNX80 Dimensions...
Страница 106: ...Post Installation Configuration Checkout 3 34 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Страница 114: ...Periodic Maintenance 6 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Страница 133: ...Appendix D Interconnect Diagrams Apollo CNX80 Installation Manual 560 0982 00 Rev D D 1 APPENDIX D INTERCONNECT DIAGRAMS...
Страница 134: ...Appendix D Interconnect Diagrams D 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Страница 164: ...Appendix E Acceptable Aircraft by Evaluation E 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Страница 166: ...Appendix F Optional Accessories Not Supplied F 2 560 0982 00 Rev D Apollo CNX80 Installation Manual NOTES...
Страница 167: ......
Страница 168: ......