DIMENSIONS AND SPECIFICATIONS, MODEL XG36-JIB
Model
Total
kW
Load
Loading kW Per Phase
Nominal Amps Per Line
208/240V 3ph
208V 3-Phase Delta 240V 3-Phase Delta
X-Y
X-Z
Y-Z
X
Y
Z
X
Y
Z
XG36-JIB
12.99
4.00
4.99
4.00
37.43 33.30 37.43 32.43 28.90 32.43
6’(1.83m) electric cord and plug is included in the supplied kit : 208V or 240V models are supplied with a #4-6AWG
cord with a NEMA 15-50P plug, kit #4524785
Clearances
Gas Pressure
Total Gas Input
Entry
Installation
Supply (min.)
Operating
Crated
Uncrated
Sides
Rear
NAT
PRO
NAT
PRO
BTU/Hr
kW
47-1/2"
(1207mm)
40-3/4"
(1035mm)
6"
(152mm)
3"
(76mm)
7.0" WC 11.0" WC 3.5" WC
3.5" WC
99,000
29.1
G
MIN 6"
[152mm]
MAX 9"
[229mm]
TOP HEATER
11 1/2"
[292mm]
GRILL PLATE 24" X 36"
[610mm X 914mm]
24"
[610mm]
36 1/8"
[918mm]
12 5/8"
[321mm]
34"
[864mm]
46 15/16"
[1191mm]
40"
[1016mm]
1 3/4"
[44mm]
TOP VIEW
FRONT VIEW
RIGHT SIDE VIEW
61 1/4"
[1556mm]
3/4"
GAS INLET
35 5/8"
[905mm]
26 3/16"
[665mm]
GRILL
PLATE
HEIGHT
TOLERANCE
+/- 1/8" [3mm]
Shipping: Weight 965Lbs/ 438Kg, 59 Cubic Feet
Garland products are not approved or authorized for
home or residential use, but are intended for commercial
applications only. Garland will not provide service,
warranty, maintenance or support of any kind other than in
commercial applications
Gas input ratings shown here are for installations up to 2,000
Ft. (610m) above sea level. Specify altitudes over 2,000 Ft.