Part # 4517957 Rev. 13 (02/10/11)
Page 8
TABLE A.
Gas Flow Rate (total)
NATURAL GAS ( ft
3
/h )
PROPANE GAS (ft
3
/h )
113
42
TABLE B.
Heat Input Per Burner
BURNER
NOMINAL HEAT INPUT
NATURAL GAS
PROPANE
kW
BTU/HR
MJ/HR
kW
BTU/HR
MJ/HR
GRIDDLE
7.32
25,000
26.37
7.32
25,000
26.37
HOT TOP
7.32
25,000
26.37
7.32
25,000
26.37
OVEN
11.14
38,000
40.08
8.79
30,000
31.65
TABLE C.
Manifold Pressure / Injector Size
BURNER
NATURAL GAS
PROPANE
Manifold Pressure
Injector Size
Manifold Pressure
Injector Size
mbar
"W.C.
DMS
mm
mbar
"W.C.
DMS
mm
GRIDDLE
11.2
4.5
42
2.4
25
10
53
1.51
HOT TOP
11.2
4.5
41
2.45
25
10
—
1.5
OVEN
11.2
4.5
31
3.05
25
10
51
1.7
NOTE:
The pressure must be measured at the pressure test nipple located on the main manifold, located at the left hand front
of the range where the hot top valve is situated, with all burners lit.
TABLE D
. Adjustment Pressure for “MIN” Valve Position
(Hot Top section)
NATURAL GAS
PROPANE
mbar
"w.c.
mbar
"w.c.
2.0
0.8
4.5
1.8
NOTE:
The pressure must be measured at the test nipple located downstream of the gas valve.
TABLE E.
Aeration Shutter Setting / Pilot Flame Length
BURNER
SHUTTER OPENING
PILOT FLAME LENGTH
NATURAL GAS
PROPANE
mm
Ins.
mm
Ins.
mm
Ins.
OVEN
19
0.750
19
0.750
25.4
1
GRIDDLE
41.3
1.625
41.3
1.625
25.4
1
HOT TOP
41.3
1.625
41.3
1.625
12.5
0.5