Part # 4520898 (05/01/14)

Page 1

Users are cautioned that maintenance and repairs must be performed by a Garland authorized service agent 

using genuine Garland replacement parts. Garland will have no obligation with respect to any product that has been 

improperly installed, adjusted, operated or not maintained in accordance with national and local codes or installation 

instructions provided with the product, or any product that has its serial number defaced, obliterated or removed, 

or which has been modified or repaired using unauthorized parts or by unauthorized service agents. 

For a list of authorized service agents, please refer to the Garland web site at http://www.garland-group.com. 

The information contained herein, (including design and parts specifications), may be superseded and is subject 

to change without notice.

Part # 4520898 (05/01/14)

© 2005 Garland Commercial Ranges, Ltd.

FOR YOUR SAFETY:

DO NOT STORE OR USE GASOLINE 

OR OTHER FLAMMABLE VAPORS OR 

LIQUIDS IN THE VICINITY OF 

THIS OR ANY OTHER

APPLIANCE

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, 
ALTERATION, SERVICE OR MAINTENANCE 
CAN CAUSE PROPERTY DAMAGE, INJURY, 

OR DEATH. READ THE INSTALLATION, 

OPERATING AND MAINTENANCE 

INSTRUCTIONS THOROUGHLY 

BEFORE INSTALLING OR 

SERVICING THIS EQUIPMENT

INSTALLATION AND 

OPERATION MANUAL

GARLAND RTCS TECHNOLOGY BUILT IN 

INDUCTION COOKERS, 

MODELS: BH/IN 2500, SH/IN 3500,SH/IN 5000, 

SH/WO/IN 3500,SH/WO/IN 5000 & SH/WO/IN 8000 

PLEASE READ ALL SECTIONS OF THIS MANUAL 

AND RETAIN FOR FUTURE REFERENCE.

THIS PRODUCT HAS BEEN CERTIFIED AS 

COMMERCIAL COOKING EQUIPMENT AND 
MUST BE INSTALLED BY PROFESSIONAL 
PERSONNEL AS SPECIFIED. 

INSTALLATION AND ELECTRICAL CONNECTION 
MUST COMPLY WITH CURRENT CODES:
IN CANADA - THE CANADIAN ELECTRICAL 
CODE PART 1 AND / OR LOCAL CODES.
IN USA – THE NATIONAL ELECTRICAL CODE 

ANSI / NFPA – CURRENT EDITION.

ENSURE ELECTRICAL SUPPLY CONFORMS WITH 
ELECTRICAL CHARACTERISTICS SHOWN ON 

THE RATING PLATE.

Garland Commercial Ranges Ltd.
1177 Kamato Road, Mississauga,
Ontaion, CANADA L4W 1X4

phone: 905 624 0260
fax: 905 624 5669

www.Garland-Group.com
www.ManitowocFoodservice.com

Содержание SH/IN 5000

Страница 1: ...MMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE IN...

Страница 2: ...Part 4520898 05 01 14 Page 2...

Страница 3: ...ngerous voltage CAUTION Indicates a hazard or unsafe practice which could result in minor personal injury or property damage Electromagnetic field IMPORTANT INFORMATION Warning Risk of fire or electri...

Страница 4: ...Part 4520898 05 01 14 Page 4...

Страница 5: ...IN 8000 11 Unit Placement 12 Installation of Operating Unit 12 Fresh Air Intake Installation 13 Instructions For Assembly Induction Built In Units 14 Guidelines For Assembly 14 Mounting Instructions 1...

Страница 6: ...ximum Relative Humidity Of Air Storage 10 90 Function 30 90 ELECTRICAL SPECIFICATIONS MODEL VOLTAGE Total KW BH IN2500 208 230 240 2 5 SH IN 3500 208 230 240 3 5 SH IN 5000 208 230 400 440 5 0 SH WO I...

Страница 7: ...tures Simple operation with rotary switch with integrated mains switch Compact module in a frame design with an induction generator controller coil ventilator glass ceramic cooking zone with power rot...

Страница 8: ...fresh air by fixing an air duct including shackle or by air openings The air exit must not to be hindered by any obstructions Electrical Supply Please observe the following rules 1 Check and ensure t...

Страница 9: ...73mm Side View of the right 0 06 1 5mm air exit air exit 4 06 103mm Ventilator Mains Cable air supply 6 73 171mm 11 02 280mm Ceran surface 10 23 260mm 10 23 260mm 12 20 310mm 12 20 310mm Front view Co...

Страница 10: ...age 10 INSTALLATION continued Cut Out for Models SH IN 3500 And SH IN 5000 The size of the cut out in the built in area must be 13 78 x 13 78 350 x 350mm the depth 9 45 240mm and the base at least 16...

Страница 11: ...ALLATION continued Cut Out For Models SH WO IN 3500 SH WO IN 5000 And SH WO IN 8000 The size of the cut out for the built in area must be 14 37 x 14 37 365 x 365mm the depth 11 81 300mm and the base a...

Страница 12: ...it In order to fix this unit on the surface of the enclosure a cut out for the power switch and the LED must considered The operator control panel has to be fixed vertically on the installation panel...

Страница 13: ...nches for dual units for the hot air to escape by installer Failure to provide adequate ventilation for the unit will result in the unit overheating nuisance shut down and potential failure of the uni...

Страница 14: ...ake sure that the in coming and outgoing exhaust air do not mix We recommend guaranteeing the supply of fresh air by using a tube with screens vent ducts or Air Intake Kit It is highly recommend that...

Страница 15: ...Part 4520898 05 01 14 Page 15 3...

Страница 16: ...Part 4520898 05 01 14 Page 16 Figure 4...

Страница 17: ...Part 4520898 05 01 14 Page 17 Figure 5...

Страница 18: ...Part 4520898 05 01 14 Page 18 Figure 6...

Страница 19: ...id injuries burning do not touch this area Use a pan suitable for induction cooking having a bottom diameter of at least 4 72 120mm only BH IN and SH IN 1 Put some water in the pan and place it in the...

Страница 20: ...stored Out Of Operation If the cooker is not in use make sure that the control knob is in the OFF position If you don t use the cooker for a long period several days unplug the unit Make sure that no...

Страница 21: ...sconnected from the electric connection Don t touch any parts inside the cooker If the supply cord is damaged it must be replaced by the manufacturer the service agent or a similarly qualified person...

Страница 22: ...identical to other similar surfaces like glass Do not use corrosive or abrasive cleaning agents such as grill and oven sprays stain and rust removers scouring powder and rough sponges 2 Before being...

Страница 23: ...ir inlet temperature must be lower than 104 F 40 C E07 Empty cooking sensing element activated Reset empty cooking protection by switching the unit off E08 Ambient temperature beyond operating range M...

Страница 24: ...normal operating conditions 2 Verify that no hot air is sucked in by the fan Reduce the ambient temperature The air inlet temperature must be lower than 104 F 40 C One phase is missing only units with...

Страница 25: ...r supplier for repair service 1 To verify if the pan is suitable use a permanent magnet and find out if it sticks on the bottom of the pan If not your pan is not suitable for induction cooking Choose...

Страница 26: ...Part 4520898 05 01 14 Page 26...

Страница 27: ...Part 4520898 05 01 14 Page 27...

Страница 28: ......