Installation  

 

RTCSmp Induction Built-In Line Dual Zone Cookers

 

 
 

 

Part # 4532285 Rev 4 (4/29/14) 

4

 

Installation 

IMPORTANT

 

 

Kitchen designers and installation contractors are responsible for designing and installing correctly the 
appropriate support structures and ventilation system for the cooking equipment.  

 

When designing kitchen cabinets for the induction equipment, please take into account all installation 
requirements, including factors such as: ease of electrical installation, size of the power conductor, and 
length of the wires. 

 

The installation, including electrical installation, must be carried out by registered installation contractors 
only. The contractors are responsible for interpreting all instructions correctly and performing the 
installation in compliance with national and local regulations. The warning signs and rating plates on the 
cooking equipment must strictly be followed. 

 

Read ALL SECTIONS carefully, comply with all requirements listed and ensure all inspection is done by 
qualified personnel.  

 

Refer to the technical data given in chapter 

3 Dimensions and Technical Specifications

 

Induction equipment that is not installed correctly will have warranty voided. See 

Warranty

, p.2. 

 

4.1

 

Location 

 

The induction unit must be installed securely in closed counters. 

IMPORTANT:

 Allow easy access to the 

unit, the air intake filter, and the cable connections for maintenance and service. 

 

The induction unit must be installed securely on a leveled and even counter surface. 

 

Do not place the induction unit on or near a hot surface or any heat producing equipment such as an 
oven or a deep fryer. 

 

Protect the induction unit from steam if the unit is placed next to high steam emitting equipment such as 
pasta cookers, steamers, and water bath. 

 

Allow easy access to the control knobs and ensure the LED lights are not obstructed. 

 

Keep the induction unit away from combustible materials, vapors or liquids. 

 

4.2

 

Ventilation 

Proper cool air intake and ventilation is essential to the reliability and functioning of the induction unit. Please 
ensure all requirements listed below are met: 

 

This induction unit is equipped with an internal air cooling system. Ensure the air supply and air exhaust 
outlets are not blocked. 

CLEARANCE

: minimum 1.18” (30mm).  

 

The maximum air flow is 70.63cfm (120m

3

 per hour) and therefore a minimal opening of 10.075 square 

inches (6500 mm

2

) is required. 

 

An optimal air intake must not be restricted by the installation. 

 

When installing the built-in unit, ensure the intake air and exhaust air are conducted separately. The in-
take air and exhaust air must not mix. To avoid build-up of hot exhaust air inside the cabinet, draw the 
exhaust air out of the cabinet.  Build up of hot exhaust air will cause the induction unit to reduce power 
or to switch-off.  

 

Ensure the Air Intake Kit is installed properly to guarantee cool air supply to the induction unit. 

 

Ensure the induction unit does not take in hot ambient air from other surrounding units and appliances, 
especially when the unit is installed close to heat generating equipment such as fryers or ovens. 

 

The air intake temperature must not exceed 104

F (40

C). 

Содержание SH DU IN 7000

Страница 1: ...with FCC part 18 ICES 001 WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCT...

Страница 2: ...G SYMBOLS This symbol alerts you to a hazardous situation that WILL or COULD cause serious bodily harm or death Be alert and implement relevant safety precautions This dangerous voltage warning symbol...

Страница 3: ...4 3 1 Built In Induction Unit Installation 9 4 3 1 1 Dimensions Dual Zone RTCSmp Built In SHDUIN7000 10000 9 4 3 1 2 Top Mount Flush Mount and Dimensions 9 4 3 1 3 Compartment Protection and Clearance...

Страница 4: ...y due to burns from contacting overheated cooking surface cookware or oil and grease Damage to the induction unit caused by using unsuitable cookware 1 2 Safety Instructions for Operator Please follow...

Страница 5: ...e operated within the limits provided in the technical specifications Please also refer to chapter 9 Important Rules for using induction equipment 1 4 Unauthorized Modification and Use of Spare Parts...

Страница 6: ...units Built with a robust construction the induction units are compact and powerful with the revolutionary RTCSmp Technology Realtime Temperature Control System with Multi Point sensing The RTCSmp Te...

Страница 7: ...lb 25kg 55 1lb 3 4 Electrical Specifications Voltage Power Conductor Size 7kW Model 208 V AC 3Ph 60Hz 7000 W 2x 3500W 22A AWG 10 400 V AC 3Ph 50Hz 7000 W 2x 3500W 11A 1 5mm2 440 V AC 3Ph 50Hz 7000 W 2...

Страница 8: ...en counter surface Do not place the induction unit on or near a hot surface or any heat producing equipment such as an oven or a deep fryer Protect the induction unit from steam if the unit is placed...

Страница 9: ...3 1 Built In Induction Unit Installation 4 3 1 1 Dimensions Dual Zone RTCSmp Built In SH DU IN 7kW 10kW 4 3 1 2 Top Mount Flush Mount and Dimensions There are two methods to install the built in unit...

Страница 10: ...connected from the unit to the bottom or to the side of the cabinet D If there is no direct path to install the air intake duct make an opening on an inner shelf or wall for the duct to pass through E...

Страница 11: ...n it is very important to use isopropyl alcohol minimum 70 or equivalent to clean the flange and the counter surfaces where the silicone adhesive will be applied To install the built in unit 1 Apply s...

Страница 12: ...panel 1 Drill holes and make the cut out using the dimensions and the actual unit provided 2 Secure the control unit to the panel with fasteners Illustration Measurements in mm and inch 4 3 2 2 Back M...

Страница 13: ...e See 4 1 Location and 4 2 Ventilation A Air Intake Filter B Air Filter Holder C Air Duct Holder D Clamp x2 E Flex Aluminum Air Duct F Silicone Adhesive PACTAN G Caulking Gun An example of an Air Inta...

Страница 14: ...should be in visible view easily accessible and labeled A blocked filter can cause electronic damage to the induction unit Refer to chapter 7 Cleaning 4 To allow hot exhaust air to escape install in...

Страница 15: ...a mains connection must not be connected to a single fault current protective switch To setup the unit for operation 1 Ensure the control knob is at the 0 OFF position ON Position Any position where...

Страница 16: ...e control knob to a position between 1 and 12 The LED indicator lamp lights up and the water is heated ON Position Any position where 0 is not pointing to the LED light The light is on OFF Position 0...

Страница 17: ...ially when you heat up oil or grease check the cooking process frequently to prevent the oil or grease from overheating and burning BROIL DRY PROTECTION The RTCSmp electronic temperature control monit...

Страница 18: ...es temperature controls in realtime To obtain the optimal results from the sensors you must always place the pan in the center of the hob which is indicated by the markings on the glass CAUTION Pans a...

Страница 19: ...ating process is engaged and the indicator light stops flashing and remains bright However the indicator light will keep flashing if the unit is not detecting any pan or an unsuitable pan is placed on...

Страница 20: ...once a week or as often as required Garland s Air Intake Filter is dishwasher safe Wipe the filter dry before inserting it back into the Filter Holder The filter is pressure fitted into the Air Filter...

Страница 21: ...ure all components relevant for safety are in perfect working order at all times Best Practice Have the induction unit examined once a year by an authorized technician 9 Important Rules Six Simple rul...

Страница 22: ...g hot air to re enter through the air intake slots Dirty air intake filter Empty pan is left on the hob when the unit is ON Symptoms When a malfunction occurs the induction unit may be in one of the f...

Страница 23: ...induction unit in normal operating conditions Verify that no hot air is sucked in by the fan Reduce the ambient temperature The intake air temperature must be lower than 104 F 40 C One phase is missin...

Страница 24: ...3 Air cooling system obstructed Internal heat sink overheated 1 Let unit cool down Verify that air inlet and outlet are not obstructed Check and clean air filter Contact your authorized service agenc...

Страница 25: ...Check sensor unit Pan empty E05 5 Rotary power switch error Defective potentiometer or broken cable 1 Check potentiometer and its wiring E06 6 Internal temperature too high generator 1 Check installat...

Страница 26: ...Troubleshooting RTCSmp Induction Built In Line Dual Zone Cookers 26 Part 4532285 Rev 4 4 29 14 NOTES...

Страница 27: ...sed correctly you will help prevent potential harm to the environment or human health which could otherwise be caused by inappropriate waste handling of this product For more detailled information reg...

Страница 28: ...S with RTCSmp TECHNOLOGY Garland Commercial Ranges Ltd 1177 Kamato Road Mississauga Ontario CANADA L4W 1X4 T 1 905 624 0260 F 1 905 624 5669 www garland group com USA Sales Parts and Service 1 800 424...

Отзывы: