Installation
RTCSmp Induction Built-In Line Dual Zone Cookers
10
Part # 4532285 Rev 4 (4/29/14)
4.3.1.3
Compartment Protection and Clearance
To protect the induction unit, the terminal block and the wire connections, we recommend isolating the unit and
the wires in a separate electrical compartment inside the cabinet.
The illustrations below show two installation versions. In Figure
A
, the unit is installed in one compartment and
the wires are exposed. In Figure
B
, the interior space of the cabinet is divided and the unit and the wires are
protected inside the upper compartment. Extra storage space is also created below the electrical compartment.
The call-outs in the illustrations indicate:
(
C
) Two methods to connect the Air Intake Kit. The duct can be connected from the unit to the bottom or to
the side of the cabinet.
(
D
) If there is no direct path to install the air intake duct, make an opening on an inner shelf or wall for the
duct to pass through.
(
E
)
IMPORTANT
Minimum clearance below the counter-surface for the unit:
204mm[8.03”] (height) x 393mm[15.47”] (width) x 653mm[25.71”] (depth).
(
F
) Hot air exhaust from the induction unit.
(
G
) Air exhaust opening installed on the cabinet.
(
H
) Fresh air supply through the intake duct.
4.3.1.4
Parallel Installation and Clearance
For parallel installation of multiple RTCSmp SHDUIN units, a gap of
minimum 12.7mm (0.5”)
, from flange to
flange, must be maintained between units. This minimum distance ensures proper air exhaust ventilation.
However, always leave enough space around the units in the cabinet for maintenance and service.
D
F
G
H
C
C
E
E
F
F
F
G
H
H
H
Figure
B
Figure
A
FRONT
FRONT
FRONT
FRONT
FRONT
FRONT
minimum
12.7 mm / 0.5”
FRONT
minimum
12.7 mm / 0.5”
minimum
12.7 mm / 0.5”