Series Portable Tap Installation Guide

This document is for informational purposes only. The information in this document, believed by Garland Technology to be accurate as of the date of publication, is subject to change without notice. Garland 

Technology assumes no responsibility for any errors or omissions in this document and shall have no obligation to you as a result of having made this document available to you or based upon the information it 

contains. Copyright 2013 © Garland Technology LLC. All Rights Reserved.

+1 716.242.8500 ◊ Buffalo, New York ◊ Garland, Texas ◊ www.garlandtechnology.com

· 

Unpack the network TAP

· 

Configure DIP switches located on the back of the TAP next to the power supply

Note:

 Anytime the configuration switches are changed the user must remove and then apply power for the changes to take effect.

To deploy the P1GCCB Portable Tap into your network, simply:

ON

1

8

2

3

4

5

6

7

1 GIGABIT | AUTO | LFP ON

Configuration Examples

ON

1

8

2

3

4

5

6

7

1OOMB | FULL | LFP OFF

Definitions:

Synchronization Mode

:  DIP Switch 1 and 2 in OFF position.  When in Synchronization Mode, all ports of the 

P1GCCB  TAP  are  Auto  MDI/MDIX,  Auto  Speed  and  Auto  Duplex  automatically.    The  TAP  will  synchronize  to 

determine the highest supported network speed, drop link across all ports, and then only advertise and link to 

the highest supported common speed on all ports.  Places the TAP in full auto mode. 

1G, 100M or 10M Speed Mode: 

(See table for Switch positions)

  

When one of the Speed Settings are selected 

then you have to option to select the Duplex (AUTO or FULL) and whether to have LFP turned on or not.

Link Failure Propagation (LFP):  

 Used mostly for HA designed networks.  It can sense a network failure and 

reflect the failure to the other side of the network allowing the network’s failover mechanism to switch over to 

the secondary network path.

Duplex:   

AUTO setting (Switch 3 in ON position default) lets the port negotiate the duplex mode with the link 

      pair (only in copper connections).  
      FULL setting forces the link to full duplex mode

Breakout

: An operating mode that allows monitoring of separate traffic streams, one for each direction of 

network traffic.

DIP Switch Setup 

(requires Power Cycle)

ON

1

8

2

3

4

5

6

7

ON

1

8

2

3

4

5

6

7

SYNCHRONIZATION | AUTO | LFP 

1OMB | FULL | LFP OFF

FailSafe

: On power loss, live network tap ports re-establish link 

with each other, resuming traffic flow between critical network 

devices.

FailSafe Operation