background image

 User Guide 

 EdgeSafe: Bypass TAP | P10GSFPA | 4.24.1 

    P10GSFPA 

 This document describes the front panel, LED indications, interfaces, rear panel, rear switch and 

 installation procedure for the P10GSFPA. The unit supports five application modes; bypass, breakout, 
 aggregate, span and span packet inject. LFP and Fail Mode (open) are supported on the network ports 
 for the bypass, breakout and aggregate modes. 

   

 Front Panel 

   

   

   

 LED Indications 

 Port 1 LFP 

 LFP LED 

 Port 1 L/A 

 Link/Activity LED 

 Port 2 LFP 

 LFP LED 

 Port 2 L/A 

 Link/Activity LED 

 Port 3 H/M 

 N/A 

 Port 3 L/A 

 Link/Activity LED 

 Port 4 H/M 

 N/A 

 Port 4 L/A 

 Link/Activity LED 

 LED 1 

 Bypass LED 

 LED 2 

 N/A 

 LED 3 

 N/A 

 Garland Technology  |  716.242.8500  |  www.garlandtechnology.com/support 

 4 

 Copyright © 2023 Garland Technology, LLC. All rights reserved. 

Содержание P10GSFPA

Страница 1: ...User Guide P10GSFPA 03 2023 Version 4 24 1 Garland Technology 716 242 8500 www garlandtechnology com support 1 Copyright 2023 Garland Technology LLC All rights reserved...

Страница 2: ...purchased products services and features are stipulated by the contract made between Garland Technology and the customer All or part of the products services and features described in this document ma...

Страница 3: ...Mode 5 Breakout Mode 5 Aggregate Mode 5 Aggregate 2 Mode 5 Span Mode 5 Span Packet Inject Mode 6 Rear Panel 6 LED Indications 6 Switch Settings 7 Installation Procedure 8 Optional Rack Mount Bracket...

Страница 4: ...ect LFP and Fail Mode open are supported on the network ports for the bypass breakout and aggregate modes Front Panel LED Indications Port 1 LFP LFP LED Port 1 L A Link Activity LED Port 2 LFP LFP LED...

Страница 5: ...Port Ingress Port 1 Port 2 Port 4 Aggregate Port Ingress Port 1 Port 2 Aggregate 2 Mode Port 1 Network Port Ingress Span Port 3 Port 4 Port 2 Network Port Ingress Span Port 3 Port 4 Port 3 Aggregate S...

Страница 6: ...Span Port Ingress Port 1 Packet Inject Port Egress Port 1 Port 3 Span Port Ingress Port 1 Packet Inject Port Egress Port 1 Port 4 Span Port Ingress Port 1 Packet Inject Port Egress Port 1 Rear Panel L...

Страница 7: ...Aggregate 3 Off 4 On 5 Off Span 3 On 4 On 5 Off Span PI 3 Off 4 Off 5 On Aggregate 2 3 On 4 Off 5 On Switch 6 7 8 N A N A 6 Off 7 Off 8 Off LFP is not supported for 1G and 10G copper applications Swi...

Страница 8: ...nd PS2 on the rear panel and plug into available power sources 4 Verify that the PS1 LED and PS2 LED on the rear panel are illuminated 5 Insert the correct SFPs for the desired speed and application T...

Страница 9: ......

Отзывы: