USER GUIDE
EdgeSafe | P10GxxBPE
P1
- Tap Network Port 1
P2
- Tap Network Port 2
Tap Colored Area
- displays the current tap status. The tap status conditions
include, GREEN Inline, RED Bypass, GREEN Inline (Forced),
RED Bypass (Forced)
Edit Pencil
- select to add a description for the tap
Description box
- enter the desired tap description, 1-15 characters
Check
- select to save the new tap description
No
- select to discard changes and close tap description
Heartbeat Settings
- select to display or change the heartbeat settings. The
heartbeat settings control taps 1-4
No. Of Lost HB Packets (10-500) - defines the number of heartbeats that must be lost for the tap
to switch from inline to bypass
Heartbeats per second (10-100) - defines the number of heartbeats that are sent per second
Tap Settings -
Changes to the tap include:
Tap Modes
Active, Force Bypass, Force inline
Fail Mode
Open
LFP
enable/disable
Reverse Bypass
enable/disable
To change the tap’s settings, place the cursor on the tap and double press the left mouse button.
The tap panel will appear.
Garland Technology | 716.242.8500 |
Copyright © 2020 Garland Technology, LLC. All rights reserved.
14