When the water system is energized, and the cavity is at a
temperature of 225°F (107°C) or higher, condensation mist
should appear from the water nozzle located above the fan,
and behind the air baffle plate (not shown) .
Nozzle
The Timer is a solid state timer on the control compartment
sidewall.
Deluxe (Fast Panel Moisture Control)
Moisture is controlled by pre-programmed choices selected
during the product cook cycle sequence . (See product cook
programming in the Operation Manual section) . Additional
moisture can be manually selected using the moisture key
pad .
COMPONENT IDENTIFICATION
Moisture Control
Mechanical Moisture Control
• The Moisture system applies water through the solenoid
in 1 second cycles .
• The scale settings are in seconds .
• Set to the low position, the water will cycle once every 60
seconds .
• Set to the 60 second position, the water will cycle 6 times
in 1 minute .
60
55
50
45
40
35
30
25
20
15
LOW
The control increases the cycle time frequencies by rotating in
a clockwise
Water pressure check:
Minimum water feed pressure:
Fully open the pressure
regulator control knob to determine what the line pressure is .
The gauge should read at least 30 psi .
Regulator pressure:
The regulator should be set at 20 psi
when the spritzer valve is energized .
One way to determine if water is being injected is to monitor
the pressure gauge . The static pressure reading will drop 6
- 10 psi when the solenoid valve is opening, or cycling .
Содержание moisture+ MP-GD-10-S
Страница 2: ...Part MPSM07 03 24 08 Page ...
Страница 4: ...Part MPSM07 03 24 08 Page ...
Страница 5: ...Part MPSM07 03 24 08 Page 5 Section One Operation Installation Manual ...
Страница 38: ...Part MPSM07 03 24 08 Page 38 ...
Страница 39: ...Part MPSM07 03 24 08 Page 39 Section Two Service ...
Страница 60: ...Part MPSM07 03 24 08 Page 60 ...
Страница 61: ...Part MPSM07 03 24 08 Page 61 Section Three Parts List ...
Страница 62: ...Part MPSM07 03 24 08 Page 62 2006 Deluxe Control Panel Gas DELUXE CONTROL PANEL MOISTURE PLUS GAS ...
Страница 66: ...Part MPSM07 03 24 08 Page 66 2006 Burners Gas Components BURNERS GAS COMPONENTS ...
Страница 68: ...Part MPSM07 03 24 08 Page 68 Revised_Interior Componets Gas INTERIOR COMPONENTS MOISTURE PLUS GAS ...
Страница 72: ...Part MPSM07 03 24 08 Page 72 Revised_Plumbing Components Gas DOOR COMPONENTS GAS MOISTURE ...
Страница 74: ...Part MPSM07 03 24 08 Page 74 Revised_Exterior Components Gas EXTERIOR COMPONENTS GAS MOISTURE PLUS ...
Страница 77: ...Part MPSM07 03 24 08 Page 77 ...
Страница 78: ...Part MPSM07 03 24 08 Page 78 ...
Страница 79: ...Part MPSM07 03 24 08 Page 79 ...
Страница 80: ......