4. Select the Fail Mode.
Open
If selected and power is lost to the unit. The traffic will switch between the
network ports.
Closed
If selected and power is lost to the unit. The traffic will go down.
5. LFP
If enabled and link is lost on one of the network ports. The TX will be disabled on
the other network port. The RX for both network ports remain on.
Figure 6 Primary-Secondary Tap (LFP)
6. Reverse Bypass
If enabled and the primary inline appliance and the secondary inline appliance
port(s) fail, loss of link or heartbeats. The TX will be disabled on both of the
network ports. The RX for both network ports remain on.
Figure 7 Primary-Secondary Tap (Reverse Bypass)
7. Revertive
If enabled and the primary inline appliance port(s) fail, loss of link or
heartbeats, the system will switch to the secondary inline appliance.
When the issue with the primary inline appliance is resolved, has link and
heartbeats. The traffic will automatically revert back to the primary inline
appliance. This option also affects the switching from bypass to inline. If
disabled, the system is designed to switch from bypass to the secondary inline
appliance. If the primary inline appliance restores first, has link and heartbeats, a
manual switch to the primary inline appliance is required. If enabled and the