Operating Instructions 

 

RTCSmp Built-In Temperature Controlled Hold-Line

 

 
 

Part # 4532288 Rev 3 (6/11/14) 

 

19 

 

Material 

Use cookware made of conductive and magnetic materials. If the pan bottom attracts a magnet, 
the pan is suitable for induction cooking. Look for cookware that is labeled “suitable for induction” 
or is marked with an induction compatible symbol.  

 

 

Size 

Minimum size:

 The bottom of the chafing dish or pan must have a diameter of at least 5” (12cm). Otherwise, 

the sensors will not sense the pan properly.   

Do not use oversized pans

 on the induction unit. The bottom of the pan must fit the glass. When a hot, 

oversized pan covers the silicone joint underneath, the heat from the pan may dry out the silicone overtime 
and cause this water tight seal to break. The induction unit may fail eventually due to penetration of liquid 
through the broken silicone seal.  

6.2

 

Proper Placement of Serving Pan 

The RTCSmp Hole-Line 1500 model has two heat-zones. Each heat-zone is equipped with the latest RTCSmp 
sensor technology which enables temperature controls in realtime. There are ten (10) sensors underneath the 
glass-top; five (5) sensors for each heat-zone. To obtain optimal results from the sensors, always place the pan in 
the center of the heat-zone.  

 

CAUTION

 

The bottom of the pan must fit the glass. A single pan must not cover more than one 
glass-top. Otherwise, electronic components of the induction unit can be damaged. 

 

DO 

A: 

Place each pan in the center of a 

heat-zone.  

B

:  Place pans within the perimeter 

of the hob. Two 1/3-pans can fit 
into one heat zone. 

DO NOT 

C

: Place pan over two hobs. 

D

:  Place part of a pan outside the 

hob. 

E

: Place metallic objects on the 

hob when the induction unit is in 
operation. 

D

E

C

B

A

Содержание IN 1500

Страница 1: ...WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INST...

Страница 2: ...e RTCSmp Heat Retaining Hold Line is referred to as induction unit DESCRIPTION OF WARNING SYMBOLS This symbol alerts you to a hazardous situation that WILL or COULD cause serious bodily harm or death...

Страница 3: ...8 3 6 Compliances 8 4 Installation 9 4 1 Location 9 4 2 Ventilation 9 4 3 Electrical Compartment Protection 10 4 4 Heat Retaining Plate Installation 11 4 4 1 Dimensions RTCSmp HOIN1500 Induction Heat...

Страница 4: ...responsible for any damages or personal injury caused by failure to observe the safety requirements Risks involved when disregarding safety precautions may include Death or injury caused by electric s...

Страница 5: ...iduals from the glass top Use only induction suitable cookware with proper size and made of proper material The induction suitable cookware should also be in good condition without any uneven arched o...

Страница 6: ...rs beneath the glass cook top The sensors can detect overheated empty pans or overheated oil and grease When this occurs the system stops the energy supply to the pan You must turn the unit off and le...

Страница 7: ...Smp Technology Realtime Temperature Control System with Multi Point sensing The RTCSmp Technology monitors the energy supply the state of the induction coil power board CPU and the cooking zone in rea...

Страница 8: ...s Top Only width x depth x height Overall Dimensions width x depth x height Weight HO IN1500 31 50 x15 75 x0 169 800 x400 x4 mm 31 50 x 15 75 x 4 49 800 x 400 x 114 mm 17kg 37 5lb 3 5 Operating Condit...

Страница 9: ...nters IMPORTANT Allow easy access to unit and cable connections for maintenance and service The induction unit must be installed securely on a leveled and even counter surface Do not place the inducti...

Страница 10: ...in one compartment and the wires are exposed Figure B The interior space of the cabinet is divided and the unit and the wires are protected inside separate compartments Extra storage space is also cre...

Страница 11: ...built for housing the unit A Cut out dimension on the counter surface 408 x 808mm 16 06 x 31 81 NOTE Dimensions include widths for silicone joints on all four 4 sides Consider adjusting cut out dimen...

Страница 12: ...tural strength and protection against water penetration we recommend the followings For stone countertop keep a minimum gap of 4 101 6mm between cut outs and provide reinforcement beam in between unit...

Страница 13: ...Before you begin the installation it is very important to use isopropyl alcohol minimum 70 or equivalent to clean the flange and the counter surfaces where the silicone adhesive will be applied To ins...

Страница 14: ...mount or back mount onto the panel Installers are responsible for choosing the appropriate fasteners for the installation The RJ 45 connectors are located on the bottom of the unit The digital display...

Страница 15: ...3 Back Mount NOTE For this type of installation the maximum thickness of the panel must not exceed 3mm or 12 gauge This restriction ensures a proper grip on the knob To mount the control unit from th...

Страница 16: ...activation and designed for a minimum fault current of 30mA Multiple generators with a mains connection must not be connected to a single fault current protective switch This induction unit is equipp...

Страница 17: ...dot Within 2 seconds the display shows the actual temperature followed by a blinking dot This means energy is being transferred to the pan and the water is heated NOTE If you are using both heating zo...

Страница 18: ...cooking process frequently to prevent the oil or grease from overheating and burning BROIL DRY PROTECTION The RTCSmp electronic temperature control monitors overheating at the pan base When an overhe...

Страница 19: ...ak The induction unit may fail eventually due to penetration of liquid through the broken silicone seal 6 2 Proper Placement of Serving Pan The RTCSmp Hole Line 1500 model has two heat zones Each heat...

Страница 20: ...ed NOTE If you are using both heating zones at the same time note that power is cycled from one zone to another This means when the left zone is active and the dot blinks the right zone is dormant and...

Страница 21: ...ter A dirty blocked air intake filter can cause electronic damage to the induction unit The Air Intake Filter is inserted into the holder at the bottom of the unit Check and clean the filter at least...

Страница 22: ...e all components relevant for safety are in perfect working order at all times Best Practice The induction unit is to be examined once a year by an authorized technician 9 Important Rules Six Simple r...

Страница 23: ...hot air to re enter the induction unit through the air intake slots Dirty air intake filter Empty pans are left on the cook top when the unit is ON Symptoms When a malfunction occurs the induction un...

Страница 24: ...e The intake air temperature must be lower than 104 F 40 C Defective induction unit Ensure knob is in OFF position and if possible and safe disconnect the unit from the power supply Contact your autho...

Страница 25: ...t air is sucked in by the fan Reduce the ambient temperature the air inlet temperature must be lower than 40 C 110 F E10 Communication BUS Check all wiring E12 Warning temperature heat sink Reduce the...

Страница 26: ...Troubleshooting RTCSmp Built In Temperature Controlled Hold Line 26 Part 4532288 Rev 3 6 11 14 NOTES...

Страница 27: ...sed correctly you will help prevent potential harm to the environment or human health which could otherwise be caused by inappropriate waste handling of this product For more detailled information reg...

Страница 28: ...D LINE with RTCSmp TECHNOLOGY Garland Commercial Ranges Ltd 1177 Kamato Road Mississauga Ontario CANADA L4W 1X4 T 1 905 624 0260 F 1 905 624 5669 www garland group com USA Sales Parts and Service 1 80...

Отзывы: