O
PERATION
Please observe the following rules:
!
Check and ensure that the supply voltage matches the voltage given on the specification plate.
!
The electrical connections must satisfy loci house installation regulations. The valid, national and local elec
trical regulations must be observed.
!
The cooker is provided with a cord and plug (60 cycle units only).
!
This induction unit is equipped with an air cooling system. Make sure that the air supply and exhaust are not
blocked (wall, fabric etc,).
!
Make, sure that the induction unit does not take in hot ambient air (concerns units standing side by side, or
one behind the other, or standing near a frying pan or an oven) .
!
The induction unit must not be placed near or on a hot surface.
!
Make sure that the induction unit does not take in grease laden air which is produced by other applications
(deep fryer, grill, frying pan). In that case you must use an air duct (available as an accessory).
!
The air intake temperature must be under 40° C The operating staff has to make sure that installation, sup
port and inspection is done by qualified personnel.
11 ½” (292mm) x 11 ½” (292mm)
11 ¼” (285mm)
3” (76mm)
Cable
for
Controls
Exhaust
Fresh Air
4 3/8” (111mm)
10 7/8” (275mm)
5 1/8”
(130mm)
6’ Corded Plug
(208/240 Volt,
60 Cycle Units Only)
12 ¼” (310mm)
12 ¼”
(310mm)
10 3/8” (260mm)
Ceran Glass
GIU 2.5 BI I
LLUSTATIONS
Page 5