Installation 

 

RTCSmp Built-In Module-Line Dual/Quad Cooktops 

 

Part # 4532415 Rev 1 (12/12/13) 

 

Page 19 

4.4.3

 

Dimensions – Mounting Frame [for glasstop size 375x650mm] 

 

4.4.4

 

Dimensions – Mounting Frame [for glasstop size 650x650mm] 

 

Содержание GI-MO/DU 7000

Страница 1: ...n Norms EN 60335 1 EN 60335 2 36 EN 62233 EMC EMV North American models ETL listed in compliance with UL 197 CSA C22 2 No 109 NSF 4 Complies with FCC part 18 ICES 001 FOR YOUR SAFETY DO NOT STORE OR U...

Страница 2: ...NG SYMBOLS This symbol alerts you to a hazardous situation that WILL or COULD cause serious bodily harm or death Be alert and implement relevant safety precautions This dangerous voltage warning symbo...

Страница 3: ...nd Operation Unit Power Switches 16 4 3 1 Location 16 4 3 2 Ventilation 16 4 3 3 Mounting Methods 16 4 3 4 Dimensions Control Unit 16 4 3 5 Dimensions Guide Holes Studs 17 4 4 Coil Carrier Sheet Ceran...

Страница 4: ...Placement of Cookware 33 6 3 Power Control 34 6 4 No Pan No Heat 35 6 5 When Unit is Not In Use 35 7 Cleaning 36 8 Maintenance 37 9 Important Rules 37 10 Troubleshooting 38 10 1Common causes for indu...

Страница 5: ...ion unit Garland is not responsible for any damages or personal injury caused by failure to observe the safety requirements Risks involved when disregarding safety precautions may include Death or inj...

Страница 6: ...ction suitable cookware with proper sizes and made of proper material The induction suitable cookware should also be in good condition without any uneven arched or partially detached bottoms Switch th...

Страница 7: ...table pan is placed on the glass top NOTE Pan with a bottom diameter smaller than 5 12 cm is not detected by the system When you remove the pan from the heating area power transfer to the pan is stopp...

Страница 8: ...induction coil power board CPU and the cooking zone in realtime RTCSmp also limits the energy supply during peak load and its special control eliminates interference noises The module line models incl...

Страница 9: ...6mm Quad 650x650x6mm 720x720x6mm Installation Frame Installation mounting frame is supplied for flush mounting the coil carrier sheet s and glass top Silicone gaskets included Five Sizes of Frames for...

Страница 10: ...0 GI MO DU 7000 10000 360 GI MO DU 7000 10000 650 GI MO DU 7000 10000 720 DU Dual with FL Full coil at end 7000 14000 360 x 360 650 x 375 720 x 360 GI MO DU 7000 14000 360FL GI MO DU 14000 650FL GI MO...

Страница 11: ...del QUAD Voltage Power Circuits Conductor Size Coils Cook Zones GI MO QU 14000 650 GI MO QU 14000 720 208 V AC 3Ph 60Hz 14000W 4x3500 W 22A 2 AWG 10 4 round coils 4 400 V AC 3Ph 50Hz 14000W 4x3500 W 1...

Страница 12: ...lass IP X0 Maximum Ambient Temperature In Storage 4 F to 158 F 20 C to 70 C In Operation 41 F to 104 F 5 C to 40 C Maximum Relative Air Humidity In Storage 10 to 90 In Operation 30 to 90 Temperature P...

Страница 13: ...ly comply with all requirements listed and ensure all inspection is done by qualified personnel Refer to the technical data given in chapter 3 Dimensions and Technical Specifications Induction equipme...

Страница 14: ...he cable connections are accessible for service 4 2 2 Ventilation Proper cool air intake and ventilation is essential to the reliability and functioning of the induction unit Please ensure all require...

Страница 15: ...t Consult an electrical or installation expert for the most appropriate location to install a cabinet exhaust fan The intake air should be filtered by an air intake filter IMPORTANT Kitchen air often...

Страница 16: ...fan must be used to remove the air away from the control unit Prevent moisture hot or greasy ambient air being drawn into the installation compartment Pay attention to the ventilation when the induct...

Страница 17: ...be inserted into the mounting frame Please follow all the location ventilation and clearance requirements listed in this section 4 4 1 Location Ventilation Distance from the control unit to the coil...

Страница 18: ...ch as an oven if and only if the ambient temperature is below 104 F 40 C An external fan must be used to remove the air away from the induction unit Prevent moisture hot ambient air or greasy fume bei...

Страница 19: ...tion RTCSmp Built In Module Line Dual Quad Cooktops Part 4532415 Rev 1 12 12 13 Page 19 4 4 3 Dimensions Mounting Frame for glasstop size 375x650mm 4 4 4 Dimensions Mounting Frame for glasstop size 65...

Страница 20: ...llation RTCSmp Built In Module Line Dual Quad Cooktops 20 Part 4532415 Rev 1 12 12 13 4 4 5 Dimensions Mounting Frame for glasstop size 360x720mm 4 4 6 Dimensions Mounting Frame for glasstop size 720x...

Страница 21: ...e silicone adhesive properly to create a water tight seal Before you begin the installation it is very important to use isopropyl alcohol minimum 70 or equivalent to clean the flanges edges and the co...

Страница 22: ...by adjusting the screws F To provide a water tight seal apply silicone sealant completely around filling any gaps between the glass and the counter top surface IMPORTANT Wait for the silicone adhesive...

Страница 23: ...r sheet must exert a constant pressure of 5mm to the Ceran glass This pressure ensures the temperature monitoring to work properly Do not allow any gap between the temperature sensors and the glass Yo...

Страница 24: ...Installation RTCSmp Built In Module Line Dual Quad Cooktops 24 Part 4532415 Rev 1 12 12 13 4 5 Models Components and Cable Connections 4 5 1 CHART 1 Module Line Round Coil Dual Models...

Страница 25: ...Installation RTCSmp Built In Module Line Dual Quad Cooktops Part 4532415 Rev 1 12 12 13 Page 25 4 5 2 CHART 2 Module Line Round Coil Quad Models...

Страница 26: ...Installation RTCSmp Built In Module Line Dual Quad Cooktops 26 Part 4532415 Rev 1 12 12 13 4 5 3 CHART 3 Module Line Full Coil Dual Models...

Страница 27: ...Installation RTCSmp Built In Module Line Dual Quad Cooktops Part 4532415 Rev 1 12 12 13 Page 27 4 5 4 CHART 4 Module Line Full Coil Quad Models...

Страница 28: ...Installation RTCSmp Built In Module Line Dual Quad Cooktops 28 Part 4532415 Rev 1 12 12 13 4 5 5 CHART 5 Module Line Full and Round Coil Quad Models...

Страница 29: ...l codes If ground fault current protective switches are used they must be provided with selective activation and designed for a minimum fault current of 30mA Multiple generators with a mains connectio...

Страница 30: ...rtion tongues of the RJ 45 cable CAN BUS are fully engaged The coil and sensor cables must be routed and MUST NOT rest on one another The coil sensor and RJ45 cables must be routed and MUST NOT rest o...

Страница 31: ...the control knob to a position between 1 and 12 The LED indicator lamp is bright and the water is heated ON Position Any position where 0 is not pointing to the LED indicator light The LED is on OFF...

Страница 32: ...ially when you heat up oil or grease check the cooking process frequently to prevent the oil or grease from overheating and burning BROIL DRY PROTECTION The RTCSmp electronic temperature control monit...

Страница 33: ...Do not use oversized pans on the induction unit The bottom of the pan must fit the glass A hot oversized pan may damage the electronic components inside the induction unit 6 2 Proper Placement of Cook...

Страница 34: ...ontrol Set the desired power level by turning the control knob and the unit is immediately ready for operation When the green indicator lamp lights up energy is being transferred to the cookware ON Po...

Страница 35: ...g and remains bright However the indicator light will keep flashing if the unit is not detecting any pan or an unsuitable pan is placed on the glass top When you remove the pan from the heating area p...

Страница 36: ...ke Filter A dirty blocked air intake filter can cause electronic damage to the induction unit Ensure to clean the Air Intake Filter at least once a week or as often as required The Air Intake Filter i...

Страница 37: ...ensure all components relevant for safety are in perfect working order at all times Best Practice Have the induction unit examined once a year by an authorized technician 9 Important Rules Six Simple...

Страница 38: ...e Inadequate ventilation causing hot air to re enter through the air intake slots Dirty air intake filter Empty pans are left on the cook top while the unit is ON Symptoms When a malfunction occurs th...

Страница 39: ...duce the ambient temperature The intake air temperature must be lower than 104 F 40 C One phase is missing for units with three phase supply only Check primary fuses Defective induction unit Ensure kn...

Страница 40: ...Check fan operation E04 4 Cook zone temperature too high Failure of sensor unit or sensor unit not connected 1 Check sensor unit Pan empty E05 5 Rotary power switch error Defective potentiometer or br...

Страница 41: ...Troubleshooting RTCSmp Built In Module Line Dual Quad Cooktops Part 4532415 Rev 1 12 12 13 Page 41 NOTES...

Страница 42: ...Troubleshooting RTCSmp Built In Module Line Dual Quad Cooktops 42 Part 4532415 Rev 1 12 12 13 NOTES...

Страница 43: ...ed correctly you will help prevent potential harm to the environment or human health which could otherwise be caused by inappropriate waste handling of this product For more detailled information rega...

Страница 44: ...with RTCSmp TECHNOLOGIES Garland Commercial Ranges Ltd 1177 Kamato Road Mississauga Ontario CANADA L4W 1X4 T 1 905 624 0260 F 1 905 624 5669 www garland group com USA Sales Parts and Service 1 800 424...