Part # 4521357 (12/07)
Page 9
Where it is not practical to do this, an automatic isolation
valve system shall be fitted which can be operated from a
readily accessible position near to the exit .
At locations where the manual isolation valve is fitted or
the automatic system can be reset a notice MUST be fitted
stating: “ALL DOWNSTREAM BURNER AND PILOT VALVES
MUST BE TURNED OFF PRIOR TO ATTEMPTING TO RESTORE
THE SUPPLY . AFTER EXTENDED SHUT OFF, PURGE BEFORE
RESTORING GAS .”
Installation Procedure
1 . Carefully remove unit from carton . All packing material
must be removed from the unit . On stainless steel units,
the protective material covering the stainless steel must
be removed immediately after unit is installed .
2 . Place the appliance in the required position and level by
means of the leveling feet .
3 . Connect the gas supply pipe work to the appliance .
The connection is made to the rear left hand side of the
appliance .
A gas isolation cock must be fitted in the supply to the
appliance . The gas isolation cock must be sited in a position
which is easily accessible to the user .
Leg Installation
The leg channel is located on the package base . This channel
must be installed when using the legs .
BOTTOM OF UNIT
LEG CHANNEL
(QTY 2)
4" [102mm]
ADJUSTABLE LEG
(QTY 4)
LEG INSTALLATION
Installation Of Counter Stands (Optional)
1 . Assemble and level the counter stand as illustrated in the
instructions found in the counter stand carton .
2 . Remove and discard the levelling bolts on the unit to be
installed on the stand .
3 . Place the unit in the desired position on the counter
stand, securing with the fasteners provided with the
counter stand .
INSTALLATION continued