Unpacking

GARLAND strongly recommends this unit be inspected for 

possible freight damage while carrier driver is on site .

1 .  Remove carton . In case of damage, all packing materials 

must be retained for carrier inspection .

2 .  Carefully inspect the broiler for any physical signs of 

damage, such as scratches, dents and missing knobs .

3 .  With carrier driver on your site, note damage on freight 

bill . Call carrier for inspection .

If you are checking equipment after carrier has departed, 

you have approximately fifteen (15) days to request a freight 

damage inspection be made by the carrier’s agent .

If concealed damage claim is filed with carrier beyond 15 

days, GARLAND cannot be held responsible and carrier will 

make it incumbent upon the consignee to offer reasonable 

evidence that the carrier was at fault .

Safety Information

WARNING: Accessible parts may become hot during use . 

Young children should be kept away .

This appliance is not intended for use by persons (including 

children) with reduced physical, sensory or mental 

capabilities, or lack of experience and knowledge, unless 

they have been given supervision or instruction concerning 

use of the appliance by a person responsible for their safety .

PRE INSTALLATION

INSTALLATION

When corresponding with the factory or your local 

authorized factory service center regarding service problems 

or replacement parts, be sure to refer to the particular unit 

by the correct model number (including the prefix and suffix 

letters and numbers) and the warranty serial number . The 

rating plate affixed to the unit contains this information . 

We suggest installation, maintenance, and repairs should be 

performed by your local authorized service agency listed in 

your information manual pamphlet .

In the event you have any questions concerning the 

installation, use, care or service of the product, write or call 

our Product Service Department .

This product must be installed by professional personnel as 

specified . Garland/U .S . Range products are not approved or 

authorized for home or residential use, but are intended for 

commercial applications only . Garland / U .S . Range will not 

provide service, warranty, maintenance, or support of any 

kind other than in commercial applications .

Rating Plate Location

The rating plate is located by removing the grease tray, it is 

located on left hand side grease slide support .

Statutory Regulations

Installation must be carried out by a competent person and 

in accordance with the relevant regulations, codes of practice 

and the related publications of the country of destination . 

In The United States of America, the installation must 

conform to the National Fuel Gas Code ANSI Z223 .1, or latest 

edition, NFPA No .54  - latest edition/or local code to assure 

safe and efficient operation . In Canada, the installation must 

comply with  CSA B149 .1 and local codes . 

Australia Specific Clause

This appliance must be installed in accordance with the 

manufacturer’s instructions, local gas fitting regulations and 

requirements of AS 5601/AG 601 installation code . All burner 

adjustments and setting should be made by a qualified gas 

technician .

Содержание G18-BRL

Страница 1: ...624 5669 Enodis UK LTD 5E Langley Business Centre Station Road Langley SL3 8DS Great Britain Phone 01753 485900 Fax 01753 4859011 Part 4525958 10 28 08 2008 Garland Commercial Industries Inc FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN C...

Страница 2: ...ould expose you to airborne particles of glass wool ceramic fibers Inhalation of airborne particles of glass wool ceramic fibers is known to the state of california to cause cancer Operation of this product could expose you to carbon monoxide if not adjusted properly Inhalation of carbon monoxide is known to the state of california to cause birth defects or other reproductive harm Keep appliance a...

Страница 3: ...TALLATION 7 Rating Plate Location 7 Statutory Regulations 7 Australia Specific Clause 7 Gas Supply 8 Gas Connections 8 Counter Line Installations 8 Location 8 Sanitary Counter Top Seal 8 Leg Installation 9 Assembly of Counter Stands 9 Installation for Units Equipped with Casters 10 Cabinet Bases 10 Assembly Of Broiler 10 Ventilation 10 OPERATION 11 Grid Rack Seasoning Instructions 11 Lighting Inst...

Страница 4: ...F18 BRL 18 457mm 25 1 8 636mm 34 1 2 876mm 190 86 21 3 45 000 13 2 GF24 BRL 24 610mm 25 1 8 636mm 34 1 2 876mm 240 109 21 4 60 000 17 6 GF30 BRL 30 762mm 25 1 8 636mm 34 1 2 876mm 290 131 29 5 5 75 000 22 GF36 BRL 36 914mm 25 1 8 636mm 34 1 2 876mm 340 154 29 5 6 90 000 26 4 NOTE Only GF series broilers with flame failure features are CE approved A REAR GAS CONNECTION 1 3 8 45mm 34 1 2 876mm 24 1 ...

Страница 5: ...4 375mm 5 125mm DIMENSIONS AND SPECIFICATIONS BROILERS continued Gas Pressure North America General International Markets Operating Manifold Pressure Natural G20 4 5 wc 11 2mbar LPG G31 10 wc 24 9mbar Australian Market Operating Manifold Pressure Natural 4 wc 1 0kPa LPG 10 wc 2 49 kpa Input Per burner MJ H Injector Dia MJ H Injector Dia 15 8 1 9 mm 15 8 1 1 mm Clearances For use in non combustible...

Страница 6: ...0 BRL 29 5 50 23 G36 BRL CAB Closed Cabinet 36 914mm Wide G36 BRL GF36 BRL 29 5 60 27 G48 BRL CAB Closed Cabinet 48 1219mm Wide G48 BRL 37 65 29 5 Many local codes exist and it is the responsibility of the Owner and the Installer to comply with those codes Garland reserves the right to change or improve product specifications without notification Garland products are not approved or authorized for...

Страница 7: ...luding the prefix and suffix letters and numbers and the warranty serial number The rating plate affixed to the unit contains this information We suggest installation maintenance and repairs should be performed by your local authorized service agency listed in your information manual pamphlet In the event you have any questions concerning the installation use care or service of the product write o...

Страница 8: ...ompletely new installation have gas lines meter size piping and piping installed and checked by a qualified gas technician H Make certain that the new piping joints and connections have been made in a clean manner and have been purged so that the piping compound chips etc will not clog pilots valves and or controls Use pipe joint sealant that is resistant to liquefied petroleum gas WARNING Check g...

Страница 9: ... a spirit level and level unit by cooking grids four 4 ways across the front and back and down the sides Assembly of Counter Stands 1 Fit stand ends together see diagram 2 Secure stand together with eight 8 10 24 machine screws eight 8 1 4 lock nuts eight 8 10 24 hex nuts provided Use only front and back pieces 3 If stand exceeds a four 4 foot length see optional cross member Optional cross member...

Страница 10: ...RL or 2 sets of 21 533mm 48 BRL long steel rods These rods are to be installed in the grooves on the support brackets which are atop the burners INSTALLATION continued Briquettes For best cooking results it is recommended that the correct amount of briquettes are installed in the broiler Refer to the table and drawing below for the proper arrangement of briquettes When all the briquettes have been...

Страница 11: ... Models G 18 24 39 36 48 BRL 1 One pilot serves two burners and is located between those burners 2 Push red spark buttons several times to ignite pilot burners 3 Ensure pilots are lit by viewing through pilot view hole on front of unit Models GF 18 24 30 36 BRL 1 Push in the valve knob and turn counter clockwise to the ignition position 2 While holding the knob fully in depress the ignitor button ...

Страница 12: ...FF at end of daily operation 7 When the grill is running never use objects such as sheet pans to cover the gill in order to hold in heat in an attempt to burn off grease or other debris Exterior Finish Cleaning Establish a regular schedule Any spills should be wiped off immediately 1 Wipe exposed clean able surface when cool with a mild detergent and hot water Stubborn residue spots may be removed...

Страница 13: ...Part 4525958 10 28 08 Page 13 ...

Страница 14: ...Part 4525958 10 28 08 Page 14 ...

Страница 15: ...Part 4525958 10 28 08 Page 15 ...

Страница 16: ......

Отзывы: