Part # 4521653 Rev 1 (03/05/13)
Page 5
GENERAL INSTALLATION
Unpacking
Carefully remove units from cartons. Remove all packing
materials from units. The protective material covering the
stainless steel should be removed immediately after the unit
is installed.
Serial Plate
All electrical ratings are shown on the serial plate of each
unit and are readily visible by opening the enameled door
located below the control panel.
Ensure electrical supply conforms with electrical
characteristics shown on the rating plate.
Statutory Regulations
The installation and connection should comply with current
codes in Canada – The Canadian Electrical Code Part 1
and / or local codes. In USA – The National Electrical Code
ANSI / NFPA – Current Edition.
Ventilation requirements can vary by country, state or
providence, please consult with local authorities having
jurisdiction for code requirements.
Installation Of Banking Plates
All units may be installed independently or banked with
other ED or GD series equipment. To ensure a matching
and permanent fit between units, two banking plates are
available for each unit to be installed. One at the front and
one at the rear of each two units being banked together. If
optional 2 1/2” (64mm) legs are supplied with unit, discard
leveling bolts and replace with legs.
1. Level each unit by adjustment of leveling bolts or legs.
Use a spirit level and level unit four ways; across front and
back and down left and right edges. Level all other units
to the first unit.
NOTE: Griddles may not rest evenly on the unit body if units
are not leveled.
2. Remove acorn nuts at rear of unit.
3. Attach one banking plate in position at rear by placing 1/4”
(6mm) diameter holes in the banking plate over the screw
holes in the rear of units and fasten by replacing the acorn
nuts removed in step 2.
4. Push units into position on counter top or back bar.
5. To secure the front, open the lower front panel, place
banking plate over the two holes (one on each unit) and
secure banking plate using sheet metal screws supplied.
REAR VIEW
FRONT VIEW
Sanitary Countertop Seal
When appliance is installed without legs on a counter top, it
must be sealed in accordance with N.S.F. standards as per the
following instructions:
1. Appliance should be located on a level counter top
surface. Complete the electrical connection.
2. Thoroughly clean the appliance bottom perimeter and
the counter top area around the appliance perimeter.
3. Lay a generous bead of silicone under the entire
perimeter of appliance bottom.
Содержание ED Series
Страница 13: ...Part 4521653 Rev 1 03 05 13 Page 13...
Страница 14: ...Part 4521653 Rev 1 03 05 13 Page 14...
Страница 15: ...Part 4521653 Rev 1 03 05 13 Page 15...
Страница 16: ......
Страница 17: ......
Страница 18: ...Pi ce n 4521653 Rev 1 03 05 13 Page 15...
Страница 19: ...Pi ce n 4521653 Rev 1 03 05 13 Page 14...