Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
34
www GarrettCom com
.
.
The following data has been collected from component manufacturer’s (Agilent’s and
Lucent’s) web sites and catalogs to provide guidance to network designers and installers.
Fiber
Port
Module
Speed,
Std.
Mode
Std.
km
fdx
(hdx)
Wave
-
length
nm
Cable
Size
μ
m
X’mitr
Output
P
T ,
dB
R’cvr
Sens.
P
R ,
dB
Worst
OPB,
dB
Worst*
distance
Km, fdx
typical
OPB,
dB
typical*
distance
Km, fdx
6KQ4V-
F10ST
10Mb
FL
Multi-
Mode
2
(2)
850 62.5/125
100/140
50/125
-15.0
-9.5
-19.5
-31
-31
-31
14
19.5
19.5
5
5.9
3.4
17
23.5
13.5
6
7
4.8
6KQ-
MST, MSC
100Mb
FX
Multi-
mode
2
(0.4)
1300 62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
14
12
5
4
6KQ-
SS
C
100Mb
FX
Single-
mode
18+
(0.4) 1300
9/125 -15 -31 14
28
17.5
35
6KQ-
SSCL
100Mb
FX
Single-
mode
40
(0.4) 1300
9/125 -5 -34 29
58
32.5
65
6KQ-
MTRJ
100Mb
FX
Multi-
mode
2
(0.4)
1300 62.5/125
50/125
-20
-23.5
-31
-31
9.0
5.5
3.0
2.0
15.8
12.2
5.5
4.0
6KQ-
MLC
100Mb
FX
Multi-
mode
2
(0.4) 1300 62.5/125
-19 -31 12
4
16
5.7
6KQ-
SLC
100Mb
FX
Single-
Mode
15+
(0.4)
1310
9/125 -15 -28 11
22
-
-
Magnum
SFP
-
LX10
1000 Mb
FX
(Gigabit)
Single-
10
1310 9/125 -10.0 -22 10
22
11
24
Magnum
SFP
-
LX25
1000 Mb
FX
(Gigabit)
Single-
25
1310 9/125 -3.0 -21 16
40
18
45
Magnum
SFP-ZX40
1000 Mb
FX
(Gigabit)
Single-
40
1550 9/125 -5.0 -22 15
60
17
68
Magnum
SFP
-
ZX70
1000 Mb
FX
(Gigabit)
Single-
70
1550 9/125 -2.0 -22 18
90
20
100
See also
http://www.garrettcom.com/techsupport/index.htm#hardware
* Note: The use of either multi-mode or single-mode fiber to operate at 100Mbps speed over long
distances (i.e., in excess of approx. 400 meters) can be achieved only if the following factors
are both applied:
•
The 100Mb fiber segment must operate in full-duplex (FDX) mode, i.e. the full-duplex
(factory default) setting for 100Mbps fiber ports must be used, and
•
The worst-case OPB of the fiber link must be greater than the fiber cable’s passive
Attenuation.
(Attenuation = Cable loss + LED aging loss + Insertion loss + safety factor)