Magnum 6KQ Managed Field Switch Installation and User Guide (04/07)
20
www GarrettCom com
.
.
For DC power input data, see Appendix B. For Dual Source, see Appendix C
.
The rugged metal case of the Magnum 6KQ will normally protect it from
accidental damage in a lab or workplace setting. Maintain an open view of the front to
visually monitor the status LEDs. Keep an open area around the unit so that cooling can
occur from convection while the unit is in operation. The 6KQ has no fans, so it is silent
when in operation. Internal electronics use the case as a heat sink, so the unit may
normally be quite warm to the touch.
3.2
Connecting Ethernet Media
The Magnum 6KQ Switches are specifically designed to support all standard
Ethernet media types within a single Switch unit. This is accomplished by using a family
of different Fiber Connectors which can be individually selected and configured per-slot.
See Section 2.2 for a description of the PMs.
The various media types supported along with the corresponding IEEE 802.3,
802.3D, 802.3u, 802.3AB and 802.3z standards and connector types are as follows:
IEEE Standard Media Type Max. Distance Fiber Connector
Fiber:
100BASE-FX
m
m
1
Fiber
2.0km (6,562 ft)
SC
sgl.m
2
Fiber
18.0km (95K ft)
SC
100BASE-FX
m
m
1
Fiber
2.0km (6,562 ft)
ST
sgl.m
2
Fiber
18.0km (95K ft)
ST
small form factor
m
m
1
Fiber
2.0km (6,562 ft)
MTRJ, MLC
small form factor
sgl.
m
1
Fiber
15 km
SLC
1
mm = multi-mode
2
sgl.m = single-mode
See
http://www.garrettcom.com/techsupport/index.htm#hardware
and click on “Power Budget
Calculations” to find fiber cable distance information.
Copper:
10BASE-T and 100BASE-TX twisted pair100m (328 ft)
RJ-45
1000BASE-TX twisted pair
100m (328 ft)
RJ-45
3.2.1
Connecting Fiber Optic ST-type, “twist-lock”
The following procedure applies to installations using a PM with ST-type fiber
connectors. This procedure applies to ports using a 6KQ module, MST-type port.
1.
Before connecting the fiber optic cable, remove the protective dust caps from
the tips of the connectors on the PM. Save these dust caps for future use.