background image

Welch Vacuum by Ingersoll Rand

1601 Feehanville Drive, Ste 550

Mount Prospect, IL 60056

Phone: (847) 676-8800 (Technical Support)

Fax: (847) 677-8606

E-Mail: [email protected]

Web-Page: www.welchvacuum.com

Copyright© 1997-2007 Gardner Denver Welch Vacuum Technology, Inc.

Welch is registered trademarks of Gardner Denver

Section 8: WARRANTY

 
This Welch Vacuum product is warranted to be free from defects in material and workmanship. This 
liability of Welch-Ilmvac under this warranty is limited to servicing, adjusting, repairing, or replacing 
any unit or component part which in the judgment of Welch-Ilmvac has not been misused, abused, 
or altered in any way or damaged by ingestion of foreign material causing impaired performance 
or rendering it inoperative. No other warranties are expressed or implied. The method of executing 
this warranty: servicing, adjusting, repairing, or replacing, shall be at the discretion of Welch-Ilmvac. 
Vacuum pumps that have been operated within a vacuum system, or other system, for any period, 
however short, will be repaired under this warranty rather than replaced.

The warranty is eff ective for one year from the date of original purchase when:
1. The warranty card has been completed and returned.
2. The product is returned to the factory or other designated service centers, freight prepaid.
3. The product in our judgment is defective through no action or fault of the user. 

If the product has become defective through misuse, abuse, alteration, or ingestion of foreign 
material, repairs will be billed regardless of the age of the product. In this event, an estimate of the 
repair costs will be submitted and authorization of these charges will be required before the product is 
repaired and returned.

Содержание WELCH 2567B-01

Страница 1: ...2567B 01 2567B 50 2567C 02 2567C 50 Warning Not recommended for pumping acid base or organic vapors or gases Warning Be sure to properly identify intake and discharge before using pump See section 2...

Страница 2: ...ons are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units conform to the SI International system of units of measureme...

Страница 3: ...discharge provisions 2 20 Electrical power 2 28 Vacuum connections 2 29 Vacuum gauges 2 30 Traps Section 03 Operation 3 10 Starting procedures 3 13 Leak detection 3 14 Pressure range 3 15 Shutdown pro...

Страница 4: ...the potential of the pump head bursting and causing possible injury to personnel in the area 1 17 All electrical products generate heat To avoid serious burns never touch unit during or immediately af...

Страница 5: ...e contact The pump should be located as closely to its system as possible in order to utilize it most e ciently The pump is rated for indoor use only Maximum altitude 2000 meters Operating temperature...

Страница 6: ...2 23 Identi cation Symbols Power O Power On 2 24 Grounding Instructions This product should be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by prov...

Страница 7: ...only used to indicate vacuum level when operating in the rough vacuum range 0 to 29 9 InHg Dial vacuum gauges give negative pressure that is pressure below atmospheric The reference point for the gaug...

Страница 8: ...is if you have droplets coming out of the exhaust port If you see droplets of water Welch recommends you use a cold trap to capture the water before entering the pump or dilute the water vapor stream...

Страница 9: ...Leak Detection The importance of eliminating all leaks in a vacuum system is obvious The pump must remove this added volume of leaked gas to maintain the desired vacuum Leaks for these pumps can be l...

Страница 10: ...n for the condition of the pump is the determination of its maximum vacuum capability This can be accomplished by blocking of the intake and reading the vacuum level on the gauge See Section 2 8 5 11...

Страница 11: ...ll Dimensions L in Inches cm 17 0 43 2 W in Inches cm 7 5 19 1 H in Inches cm 12 0 30 5 Shipping Weight lbs Kg 24 10 9 Shipping Dimensions L in Inches 21 5 W in Inches 12 5 H in Inches 16 Catalog Numb...

Страница 12: ...12 6 11 Pumping Speed Curves...

Страница 13: ...6 12 Dimensional Drawing 244 0 CORD ASSY 8 25 4X 8 32 UNC 2B THRU 7 09 6 67 9 45 INTAKE NIPPLE FOR 3 8 TUBING MUFFLER 11 67 OUTLET INLET 182 6 3 50 5 38 7 19 296 4 240 0 209 5 9 61 180 0 169 4 88 9 13...

Страница 14: ...ice Kit Seal Kit Suction Foot Kit 2567K 03 2567K 04 2500K 04 1 2 2567K 01 Connecting Rod Assembly 2 2 2 2567K 02 Valve Plate Ass y 2 3 2 O Ring Cylinder 2 2 4 2 O Ring Valve Plate 2 2 5 1 1412C Exhaus...

Страница 15: ...2567C 50 7 21 System Components available as kit Cat No 2565K 50 vacuum regulator with separator jar Qty 2565K 50 Description for regulator separator jar 1 Jar Assembly 1 Needle Valve Miniature 1 Inst...

Страница 16: ...other warranties are expressed or implied The method of executing this warranty servicing adjusting repairing or replacing shall be at the discretion of Welch Ilmvac Vacuum pumps that have been opera...

Отзывы: