background image

 

RFL-7-500     Page  31 

 

Americas 
 
Gardner Denver, Inc. 
Industrial Products Groups – Americas 
1800 Gardner Expressway 
Quincy, IL. 62305 
Toll Free: 1-800-682-9868 
Phone: 217-222-5400 
Fax: 217-221-8780 
 
Email: [email protected] 

Australia 
 
Gardner Denver Ind. Australia Pty Ltd 
30 Bearing Road 
Seven Hills 
New South Wales 
2147 Australia 
Phone: +61 2 96207000 
Fax: +61 2 96207955 
 
Email: [email protected] 

Belgium 
 
Gardner Denver Belgium N.V. 
Luithagen 7A 
Haven 200 
B-2030 Antwerpen 
Belgium 
Phone: +32 (0)3 5415040 
Fax: +32 (0)3 5416509 
 
Email: [email protected] 

 

 

 

France 
 
Gardner Denver France SA 
Division Compresseurs 
42, rue de Montmurier, BP 604 
38070 Saint-Quentin-Fallavier, France 
Phone: +33 (0)474941673 
Fax: +33 (0)474941689 
 
Email: [email protected] 

Germany 
 
Gardner Denver Deutschland GmbH 
Am Dorn 14 
48308 Senden 
Germany 
Phone: +49 (0)253634840 
Fax: +49 (0)25363484010 
 
Email: [email protected] 

Netherlands 
 
Gardner Denver Nederland BV 
Barwoutswaarder 3B 
3449 He Woerden 
The Netherlands 
Phone: +31 (0)348410150 
Fax: +31 (0)348418079 
 
Email: [email protected] 

 

 

 

UK Sales & Service 
 
Gardner Denver UK Ltd 
PO Box 468 
Cross Lane, Tong 
Bradford, West Yorkshire 
United Kingdom 
BD4 0SU 
Phone: +44 (0)1274 683131 
Fax: +44 (0)1274 651006 
 
Email: [email protected] 

Spain 
 
Gardner Denver Iberica S.L. 
Calle Primavera, 20 
Poligono Industrial Las Monjas 
28850 Torrejon de Ardoz 
Madrid, Spain 
Phone: +34 (0)916560056 
Fax: +34 (0)916770496 
 
Email: [email protected] 

Rest of the World 
 
Gardner Denver Ltd 
PO Box 178 
Springmill Street 
Bradford, West Yorkshire 
United Kingdom 
BD5 7HW 
Phone: +44 (0)1274 718100 
Fax: +44 (0)1274 655272 
 
Email: [email protected] 

Содержание RFL 102

Страница 1: ...PD BLOWERS VACUUM PUMPS RFL SERIES Owner s Manual RFL 102 RFL 7 500 Version 03 April 11 2018...

Страница 2: ...2 PREVENTION OF SUCTION INTAKE OF DIRT AND RESIDUE 12 5 2 1 Suction Pipe 12 5 2 2 Vacuum Intake Filter 12 5 2 3 Safety Dome 12 5 2 4 Safety Tank 12 5 2 5 Combination Air Filter 13 5 3 NOISE SUPPRESSI...

Страница 3: ...cking Intervals 22 7 3 POSSIBLE OPERATING ERRORS 22 7 4 PRECAUTIONS FOR LONG STANDSTILL PERIODS 23 7 5 RINSING AFTER MACHINE WAS OVER SUCKED 23 7 6 PROCEDURE IF FAULTS OCCUR 23 8 MAINTENANCE 25 8 1 WA...

Страница 4: ...e used for long periods Store in a dry heated building Handle with care and keep the inlet and discharge ports covered Rotate the drive shaft of the machine monthly in the direction shown by the arrow...

Страница 5: ...6 Information This symbol indicates information of particular interest to the operator of the machine 2 7 Points to Note The compressor vacuum pump has been constructed according to the latest techno...

Страница 6: ...e pipe between the machine and the shut off valve Release pressure manually at the safety valve or vent the machine at the ventilation valve Pay attention to the manometer The drive prevention device...

Страница 7: ...ssion operation2 psig 2 9 Nominal vacuum1 psiA 2 9 Max permitted vacuum up to 3 minutes per hour 1 psiA 2 18 Power requirement at drive shaft for 2 bar pressure hp 41 6 Min speed rpm 1000 Max speed rp...

Страница 8: ...3 2 Dimensions Fig 3 1 Dimensions of RFL 102 9 Fig 3 2 Hydraulic Drive Dimensions Hydraulic Drive Details Kit Number TEN009820 Motor Flange Type SAE C 4 BOLT Gearbox Details Kit Number TEN009819 Motor...

Страница 9: ...ng Hours h 40 Oil Level Checks per Day once 3 4 Cooling Air cooling is carried out by means of two fans mounted at either end of the rotor shaft which draw in cool air to pass over the cooling fins on...

Страница 10: ...the covers on inlet and discharge ports only at the time of actual installation Rotate the drive shaft of the machine monthly in the direction shown by the arrows on the machine body The protective c...

Страница 11: ...Manometer 4 Vacuum relief valve 5 Overpressure safety valve 6 Venting shut off valve 7 Vacuum intake filter 8 Compressor Vacuum pump 9 Thermometer 10 Manometer 11 Silencer Oil separator Fig 5 2 Machin...

Страница 12: ...easily accessible be protected from dirt flying debris and water splash provide enough clearance for the connection of the suction and pressure pipes provide easy access for maintenance e g oil fille...

Страница 13: ...nants and reduces suction noise The filter element must be removable for maintenance 5 2 3 Safety Dome The safety dome on the vehicle tank must include not only a float valve but also a swell protecti...

Страница 14: ...102 is far below the value permitted for commercial vehicles To preserve these values when the machine is installed the low noise installation is necessary Air noise suppression by noise suppressing...

Страница 15: ...d buffers to support the belt forces and a counter bearing on the side of the machine opposite the belt drive are necessary 5 4 Safety and Monitoring Features The operating safety of the machine i e o...

Страница 16: ...tted operating pressure It must be able to expel the entire flow capacity of the compressor vacuum pump The valve must also be fitted with a manual ventilation device If the safety valve is mounted fi...

Страница 17: ...monitor on the machine with a display which is visible to the operator In any case the rotational speed must be monitored after assembly of the compressor vacuum pump and operating instructions for th...

Страница 18: ...down a V Belt drive is recommended The nominal rotation speeds as in section 3 1 must be observed Units Belt profile SPA Belt pulley diameter DW mm in 200 2 874 Max operating pressure for V Belt driv...

Страница 19: ...base plate Flatness within 0 010 in Can be driven by direct coupling flexible coupling or V belt drive Check oil level every 24 hours of operation Change oil when gear drive has been in service for 50...

Страница 20: ...rmation concerning the operation and maintenance of the machine 6 2 Lubricating Oil See section 6 7 for types of oil For the RFL 102 single grade oils are prescribed Use of multi grade oils may result...

Страница 21: ...ubricating oil type for the RFL 102 is SAE 30 For ambient temperatures above 40 C use SAE 40 For ambient temperatures below 0 C use SAE 20 For the RFL 102 single grade oils are recommended Use of mult...

Страница 22: ...lubricating oil For the lubricating oil specification see section 6 7 7 2 1 Safety Valve A non lockable safety valve must be installed in the pressure line after every compressor It must be set so tha...

Страница 23: ...the entire volume via the safety valve when the pressure line is closed Vacuum too low see section 7 2 or Rating Plate Compressed air temperature too high see section 7 2 Poor cooling cooling air sup...

Страница 24: ...a malfunction occurs the following table may provide the cause and solution to the problem Fault Possible cause Elimination Volume flow performance of compressor vacuum pump deteriorates Vacuum filter...

Страница 25: ...to rotation speed limits Discharge pressure too high Adhere to nominal pressure activate check safety valve Manometer gives incorrect reading Replace manometer Exhaust silencer blocked Replace exhaus...

Страница 26: ...r vacuum pump Maintenance points Type of work See section Maintenance intervals 1 week 1 month 3 months Other Coolant air path Check clean 8 2 1 Compressor Vacuum pump Clean 8 2 2 Vacuum filter Clean...

Страница 27: ...ine must be cleaned weekly Washing or rinsing with high pressure water jets may result in water penetration which can cause failure of the compressor vacuum pump Carefully clean remove any dirt on the...

Страница 28: ...sion Drive guards must only be removed when the machine is at a standstill and the vehicle engine is switched off V Belts and the V Belt tension must be checked every week and if necessary tightened o...

Страница 29: ...moved Insert a slide hammer into the M6 tapped end of the cylinder pin 4 and carefully remove the guide plate 2 valve seat 3 and pin from the body After careful cleaning check the valve seat for the q...

Страница 30: ...nd measure the distance to the rotor surface with a reliable depth gauge see fig 8 2 Fig 8 2 Vane Wear Inspection The dimension should not exceed 5mm If the wear limit reaches 5mm the rotor vanes must...

Страница 31: ...meet the latest legal requirements When ordering spare parts please provide the following information Example Machine type RFL 102 Machine no L0001 Year of manufacture 2015 Part no TW34278100 Quantit...

Страница 32: ...tact lyon gardnerdenver com Germany Gardner Denver Deutschland GmbH Am Dorn 14 48308 Senden Germany Phone 49 0 253634840 Fax 49 0 25363484010 Email info de gardnerdenver com Netherlands Gardner Denver...

Страница 33: ...NOTES...

Страница 34: ...NOTES...