13-11-608 Page 10
Service doors are provided for maintenance access. Be sure to allow enough space around the unit for
the doors to be opened and removed as necessary for service procedures. The enclosure doors are held
by two latches and lift away from the enclosure. The air filter, water filters, and water treatment cartridge
are easily accessible through a side or end door.
DANGER
Do not operate the compressor with the belt guard removed. Exposed belts
may cause injury to personnel.
COMPRESSOR WATER SPECIFICATION
- The compressor unit is supplied with an integral filtration
system (by reverse osmosis) to ensure adequate quality levels for the injection water system. In order to
maintain the water filtration system working at peak efficiency, the incoming water supply must meet a
number of requirements. Please refer to the “RO Water Filter”, Section 8, of this manual for details.
WARNING
Back flow Preventers must be installed on the potable water supply line to the
compressor to prevent high pressure air from blowing into the water supply.
WARNING
Use of compressor initial fill and make-up water not meeting all water
specification standards noted may result in contamination of the discharge air
stream.
WARNING
The use of make-up water exceeding the quality units outlined in the “RO Water
filter”, Section 8, may result in damage to critical compressor components by
corrosion and/or scaling action of impurities in the water.
NOTICE
Water may no longer be potable after use in the compressor.
COOLING WATER SPECIFICATION
- Water-Cooled water and aftercooler cores must be provided with
an adequate source of coolant. The following requirements must be met:
Содержание PUREAIR EWD99E
Страница 7: ...13 11 608 Page 2 Figure 1 2 PACKAGE ILLUSTRATION AIR COOLED 302EWD797 A Ref Drawing...
Страница 8: ...13 11 608 Page 3 Figure 1 3 PACKAGE ILLUSTRATION WATER COOLED 303EWD797 A Ref Drawing...
Страница 9: ...13 11 608 Page 4 Figure 1 4 WATER COOLED SCHEMATIC 300EWD797 D Ref Drawing...
Страница 10: ...13 11 608 Page 5 Figure 1 5 AIR COOLED SCHEMATIC 301EWD797 D Ref Drawing...
Страница 30: ...13 11 608 Page 25 Figure 4 2 FLOW CHART FOR SETUP PROGRAMMING 300EWC1255 Ref Drawing...
Страница 44: ...13 11 608 Page 39 301EWD546 B Ref Drawing Page 2 of 2...
Страница 45: ...13 11 608 Page 40 Figure 4 5 WIRING DIAGRAM WYE DELTA WITH EXPANSION BOARD 302EWD546 B Ref Drawing Page 1 of 2...
Страница 46: ...13 11 608 Page 41 302EWD546 B Ref Drawing Page 2 of 2...
Страница 47: ...13 11 608 Page 42 Figure 4 6 WIRING DIAGRAM FULL VOLTAGE LESS STARTER 303EWD546 B Ref Drawing Page 1 of 2...
Страница 48: ...13 11 608 Page 43 303EWD546 B Ref Drawing Page 2 of 2...