Measured in an open area as per ISO 2151, tolerance 3 dB(A).
At CompAir, our philosophy is to continually improve our products. We therefore reserve the right to alter technical
data without prior notice.
9.6.6
L110 RS, 50Hz + 60Hz, air-cooled "A", water-cooled "W"
L110 RS,
50Hz + 60Hz, air-cooled "A" + water-cooled
"W"
L110 RS,
Maximum operating pressure
[bar]
13.0
Minimum operating pressure
[bar]
5.0
Ambient temperature
[°C]
1 / 45
min speed
max. speed
Volume flow / Disch. Pressure [7.5 bar]
*)
[m
3
/min]
5.27
21.46
Volume flow / Disch. Pressure [9 bar]
*)
[m
3
/min]
5.24
19.69
Volume flow / Disch. Pressure [10 bar]
*)
[m
3
/min]
5.19
18.63
Volume flow / Disch. Pressure [13 bar]
*)
[m
3
/min]
6.66
16.21
Aftercooler outlet temperature above ambient
temperature
"A" = [°C]
"W" = [°C]
8
9
Sound pressure level (ISO 2151)
**)
"A" [dB(A)]
"W" [dB(A)]
72 / 76 (50Hz) ; 72 / 77 (60Hz)
72 / 76 (50Hz) ; 72 / 77 (60Hz)
Rated speed of drive motor
[kW]
110
Total current consumption during load operation
(380V) / (400V) / (460V)
"A" [A]
"W" [A]
235 / 217 / 194
225 / 214 / 186
Electric motor
IP55 (IE3) - IEC
60034-2-1 ECA Qualifying
Rated speed of drive motor
[rpm]
650 / 2620
Rated speed of fan motor
"A" [kW]
2.6 (50Hz) ; 6.6 (60Hz)
Rated speed of fan motor
"W" [kW]
0.37 (50Hz) ; 0.66 (60Hz)
Recommended cable cross-section (380 / 400 /
460V)
[mm
2
]
3 x 95 PE50 / 3 x 95 PE50 /3 x 70 PE35
Recommended fuse rating (time-delayed) (380 /
400 / 460V)
[A]
3 x 315 / 3 x250 / 3 x 224
Cooling air volume flow
"A" [m
3
/
min]
227 (50Hz) ; 248 (60Hz)
Cooling air volume flow
"W" [m
3
/
min]
100
Cooling air outlet temperature above ambient
temperature
"A" [°C]
32 (50Hz) ; 27 (60Hz)
Residual pressure at ambient temperature
"A" [Pa]
80 / 40 [35 °C / 45 °C] (50Hz) ;
90 / 60 [35 °C / 45 °C] (60Hz)
Cooling water quantity (ΔT = 14 K)
"W" [l/min]
125 @ Δp = 1.4 bar
Chart 9-8: Technical data; L110 RS, 50Hz + 60Hz, air-cooled "A", water-cooled "W"