manualshive.com logo in svg
background image

Содержание 919.727320

Страница 1: ...on top of the motor shroud or on the bar code label on the rear of air tank 2 The Date Code Number can be found on the bar cede label on the rear of the air tank 3 The Serial Number can be found on the bar code labe on the rear of the tank 4 The Tank Registration Number is located on the metal data plate which is welded onto the backside of the air tank This data plate is painted the same color as...

Страница 2: ...is air compressor is used for commercial or rental purposes the warranty will apply for ninety days 90 from the date of purchase This Craftsman Air Compressor warranty gives you specific legal rights and you may have other rights which vary from province to province Sears Canada Inc Toronto Ont M5B 2B8 This manual contains information that is important for you to know and understand This informati...

Страница 3: ...UCT WHEN IT IS OPERATING s o oo s o 1 AIR TANK THE FOLLOWING CONDITIONS COULD LEAD TO A WEAKENING OF THE TANK AND RESULT IN A VIOLENT TANK EXPLOSIOI_AND COULD CAUSE PROPERTY DAMAGE OR SERIOUS INJURY WHAT CAN HAPPEN 1 FAILURE TO PROPERLY DRAIN CONDENSED WATER FROM THE TANK CAUSING RUST AND THINNING OF THE STEEL TANK 2 MODIFICATIONS OR ATTEMPTED REPAIRS TO THE TANK 3 UNAUTHORIZED MODIFICATIONS TO TH...

Страница 4: ...TION NEVER INHALE AIR FROM THE COMPRESSOR EITHER DIRECTLY OR FROM A BREATHING DEVICE CONNECTED TO THE COMPRESSOR WORK IN AN AREA WITH GOOD CROSS VENTILATION READ AND FOLLOW THE SAFETY INSTRUCTIONS PROVIDED ON THE LABEL OR SAFETY DATA SHEETS FOR THE MATERIAL YOU ARE SPRAYING USE A NIOSWMSHA APPROVED RESPIRATOR DESIGNED FOR USE WITH YOUR SPECIFIC APPLICATION RISK OF ELECTRICAL SHOCK WHAT CAN HAPPEN ...

Страница 5: ... continue to use your accessory When the tank pressure drops to a certain low level and the pressureswitch lever is in Auto the motor will restart automatically The low pressureat whichthe motor auto matically restarts is called cut in pressure Cut Out Pressure When you turn on your air compres sor and it begins to run air pressure in the air tank be gins to build It builds to a certain high press...

Страница 6: ...at its cut out pressure setting the safety valve will protect the tank against high pressure by pop ping out at its factory set pressure slightly higher than the pressure switch cut out setting Regulator The air pressure coming from the air tank is controlled by the regulator The regulator control knob is a vibration proof design Lift the regulator knob to en gage and depress the knob to lock Turn...

Страница 7: ...ord hav ing a grounding wire with an appropriate grounding plug The plug must be used with an outlet that has been in stalled and grounded in accordance with all local codes and ordinances The outlet must have the same configu ration as the plug DO NOT USE AN ADAPTER Inspect the plug and cord before each use Do not use if there are signs of damage IMPROPER GROUNDING CAN RESULT IN ELECTRICAL SHOCK ...

Страница 8: ...g it counterclockwise The air tank will fill to cut out pressure and then the motor will stop 1 2 Before attaching air hose or accessories make sure the AUTO O lever is set to O and the air regulator is closed AKach hose and accessories TOO MUCH AIR PRESSURE CREATES A HAZARDOUS RISK OF BURSTING CARE FULLY FOLLOW STEPS 3 AND 5 BELOW EACH TIME THE COMPRESSOR IS USED I _JLIJBL e _l Compressed air fro...

Страница 9: ...valve and that the spring holds the disc in the upper closed position The check valve may be cleaned with a solvent such as paint and varnish remover 7 Apply a Teflon based pipe sealant to the check valve threads Reinstallthe check valve tam clockwise 8 Replace the pressure release tube and fitting 9 Replace th _ t t _ be and tighten top and bottom nuts 10 Replace th_ shroud If the safety valve do...

Страница 10: ...place the pressure switch Returnthecompressorto SearsService Center to check and adjust or replace switch Tighten fittings using teflon tape where air can be heard escaping Check fittings with soapy water solution DO NOT OVER TIGHTEN Return to Sears Service Center for replace ment of pressure switch Check to see ifthe pin in the bottom of the pressure release valve is stuck Ifit does not move free...

Страница 11: ... sanding area Check and reprace if required Remove and clean or replace Tighten fittings Motor will start automatically when tank pressure drops below cut in pressure of pressure switch 1 2 3 4 Check fuse box for blown fuse and replace if necessary Reset circuit breaker Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit Check for proper f...

Страница 12: ...13 ENG D20417 Rev 1 6 28 00 ...

Страница 13: ...ake and model no of the merchandise and the name and number of the part you wish to order If calling locally please use one of the following num bers Regina 566 5124 Montreal 333 5740 Toronto 744 4900 Halifax 454 2444 Kitchener 894 7590 Ottawa 738 4440 Vancouver 420 8211 WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION PART NUMBER PART DESCRIPTION MODEL NUMBER NAME OF ITEM All part...

Отзывы: