10 Service and Maintenance
49
10.10
Screw connections
Check the air and oil system screw connections in
accordance with the maintenance schedule and tighten
if necessary.
10.11
General maintenance and cleaning
WARNING
Danger when cleaning system parts with
compressed air: Small parts propelled at
high speed by compressed air can
penetrate the skin or destroy an eye.
•
Do not aim the compressed air at people
CAUTION
Fire hazard from oil residues
Oil residue and other deposits must be
removed from the compressor coolers
which are exposed to hot air in accordance
with the user manual.
The screw compressor should be blown off with
compressed air at the given intervals (do not aim the
compressed air at people), especially:
Controller components
•
Fittings
•
Air end block
•
Cooler
•
Electric Motor
10.12
Clean/replace cool air intake and
control box filter pads
DANGER
Only perform checks and carry out work on
the screw compressor when the unit is out
of operation, depressurized, and secured
from being switched on again!
Fig. 28
1 Cool air intake filter pad
2 Filter pad mounting screw
Replace the filter pad as follows:
•
Remove the mounting screws (- 2 - Fig. 28).
•
Remove and clean the filter pad (- 1 - Fig. 28). If
there is damage, replace.
•
Place the filter pad back in the acoustic gate
(- 3 - Fig. 28).
•
Secure the filter pad with mounting screws.
Cleaning:
The filter pad can be cleaned by brushing or washing.
NOTICE
The filter pad may not be installed while wet or
moist!
Содержание L23
Страница 2: ......
Страница 61: ...12 Appendix 59 Fig 33 All dimensions in inches ...
Страница 62: ...12 Appendix 60 Fig 34 All dimensions in inches ...
Страница 63: ......