6. Preparations for commissioning
29
Fig. 12
Fig. 13
6.5
Oil level check
Danger
Only check the oil level when the screw
compressor unit is out of operation and
depressurized!
The pressure reservoir can be under pressure and
the oil hot. Warning: Danger of scalding!
Do not spill oil! Check for leakage!
Fig. 14
1 Oil filler cap R1"
2 Oil-level
indicator
3 Maximum oil level
4 Minimum oil level
Important
Do not mix oils of different specifications.
Machines which are delivered without oil must first
be filled to the max. mark in the pressure reservoir
sight glass (see also chapters 9.4 and 9.15)
Check the oil level as follows:
Switch off the screw compressor unit by pressing
the button
(Fig. 16).
Wait at least 5 minutes for the oil to settle and for
the air to disperse
The oil level is checked with the help of the
transparent plastic tube at the pressure reservoir
(- 2 - Fig. 14) after every stop and at regular
intervals. If required, top up oil
Also see chapter 9 “Service and maintenance”