13-8-638 Page 34
13. Open the air service valve.
14. Run the unit and check for leaks.
COMPRESSOR OIL SYSTEM CHECK
- The following readings are based on ambient temperature of
80
°
F (27
°
C) with the system in good condition. The compressor should be at operating temperature at
the time of the checks. One-half hour of loaded operation is usually sufficient to reach level-out
operating temperatures.
Air and Oil Discharge Temperature
- 160
°
F to 180
°
F (71
°
C to 82
°
C) - Check with a thermometer at
the discharge housing.
Compressor Oil Inlet Temperature
- 150
°
F to 165
°
F (66
°
C to 74
°
C) - Install a tee at the oil filter outlet
and check with a thermometer.
Oil Inlet Pressure
- Check at the fitting in the line near the compressor oil inlet. With air receiver
pressure at 100 psi (6.9 bar), oil inlet pressure should be 80 to 90 psig (5.5 to 6.2 bar).
Oil Cooler Oil Pressure Differential
- Check differential across the oil system by measuring oil inlet
pressure as described above.
Oil Cooler Temperature Differential
- The oil temperature differential depends on the temperature of the
air at the oil cooler fan and cleanliness of the core faces. As ambient temperatures and core restrictions
increase, the oil cooler outlet temperature will increase. The oil inlet temperature is approximately the
same as the air discharge temperature.
Содержание INTEGRA EFD99B
Страница 9: ...13 8 638 Page 2 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 A Ref Drawing...
Страница 12: ...13 8 638 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 13: ...13 8 638 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 29: ...13 8 638 Page 22 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 1 of 2...
Страница 30: ...13 8 638 Page 23 Figure 4 4 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 2 of 2...