13-8-638 Page 25
CAUTION
Specific AEON
™
lubricants are recommended for use in this equipment. Other
lubricants may cause excessive carryover or compressor damage. Do not mix
different types of lubricants or use inferior lubricants. Check the decal on the
oil reservoir for lubricating coolant specification.
HIGH TEMPERATURE OPERATION
- If the discharge temperature is sustained between 200
°
F-210
°
F.
for a period of more than four (4) hours due to continuing high ambient air temperature, use Gardner
Denver AEON 9000SP Lubricating Coolant which is a superior synthetic lubricant. Short periods of up to
four (4) hours of sustained discharge temperatures up to 210
°
F. do not require a change from the
recommended year-round lubricant AEON 4000.
COLD AMBIENT OPERATION
- See “Installation for Cold Weather Operation,” page 10 and Figure 2-3,
page 9.
PROCEDURE FOR CHECKING OIL LEVEL
(Figure 5-4, page 30) - Check the oil level when the
compressor is shutdown and the oil/air mixture has separated. The oil should be visible in the white
range (a flashlight must be used) of the gauge. If there is only red showing on the gauge, the oil level is
too high and must be drained. If the oil level is in the red range below the white range, the oil level is too
low and oil must be added.
ADDITION OF OIL BETWEEN CHANGES
– Oil must be added when the oil level is below the min. range
on the oil gauge. The oil must be checked with the machine shutdown, blowndown and the air/oil mixture
settled out to air and oil.
DANGER
Air/oil under pressure will cause severe personal injury or death. Shut down
compressor, relieve system of all pressure, disconnect, lockout and tagout
power supply to the starter before removing valves, caps, plugs, fittings, bolts
and filters.
DANGER
Compressor, air/oil reservoir, separation chamber and all piping and tubing
may be at high temperature during and after operation.
CAUTION
Excessive oil carryover can damage equipment. Never fill oil reservoir above
the max. range of the gauge.
To add oil, follow these steps:
1.
Be sure the unit is completely off and that no air pressure is in the oil reservoir.
2.
Disconnect, lockout and tagout the power supply to the starter.
Содержание INTEGRA EFD99B
Страница 9: ...13 8 638 Page 2 Figure 1 2 COMPRESSOR ILLUSTRATION 300EFD797 A Ref Drawing...
Страница 12: ...13 8 638 Page 5 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 13: ...13 8 638 Page 6 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 29: ...13 8 638 Page 22 Figure 4 3 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 1 of 2...
Страница 30: ...13 8 638 Page 23 Figure 4 4 WIRING DIAGRAM FULL VOLTAGE 303EFD546 D Ref Drawing Page 2 of 2...