HF-7-602 Page 16
PIPING
Inlet and discharge connections on all blowers are large enough to handle maximum volume with
minimum friction loss. Reducing the pipe diameter on either inlet or discharge will only create additional
line loss and increase the overall pressure differential.
Excessive weight of piping and fittings will cause internal misalignment and premature wear. Never allow
the blower to carry the weight of the pipe. If possible, a spool or sleeve-type expansion joint should be
installed between the unit and the piping. Where a flexible connection is not practical, the weight of the
rigid connection must be separately supported. All system piping must be cleaned internally before
connecting to the blower.
Gardner Denver blowers are shipped dry from the factory. Do not attempt to operate the blower
before following proper lubrication instructions. Permanent damage to the gears, bearings and
seals will occur.
Содержание HELIFLOW HYEL AA
Страница 13: ...HF 7 602 Page 12 FIGURE 2 1 VERTICAL BLOWER MOUNTING CONFIGURATIONS AND OUTLINE 303HYE800 A Ref Drawing...
Страница 14: ...HF 7 602 Page 13 FIGURE 2 2 514 BLOWER MOUNTING CONFIGURATIONS AND OUTLINE 302HYE800 C Ref Drawing...
Страница 26: ...HF 7 602 Page 25 Figure 5 3 CARRIER SLINGER DRIVER EQ144211 3 Figure 5 4 INSERT DRIVER EQ144211 4...
Страница 27: ...HF 7 602 Page 26 Figure 5 5 FALSE BEARING EQ144211 5...
Страница 29: ...HF 7 602 Page 28 Figure 5 8 HAND CRANK EQ144211 8...
Страница 30: ...HF 7 602 Page 29 Figure 5 9 MECHANICAL SEAL DRIVER EQ144211 9...
Страница 31: ...HF 7 602 Page 30 Figure 5 10 FALSE BEARING SPACER EQ144211 10...
Страница 44: ...HF 7 602 Page 43 SECTION 8 PARTS LIST HYEL_AA 300HYE810 D Ref Drawing...
Страница 55: ...HF 7 602 Page 54 SECTION 10 PARTS LIST HYEL_AB 301HYE810 B Ref Drawing...
Страница 58: ......
Страница 59: ......