GSRN10-2250A-SM 

Page 5 of 10 

 

CONDENSATE DRAINS 

 

The condensate system is at line pressure and can cause personal injury or equipment 
damage when discharging.  Securely anchor the drain pipes or tubes prior to dryer 
operation. 
Prior to any maintenance isolate and depressurize condensate drain valves. 

 

Internal Float Drain 

GSRN-10 through GSRN-40 

Electronic Drain Assembly 

GSRN-50 through GSRN-2250 

 

 

 

 
When maintaining float drains 
depressurize the dryer & drain prior 
to work initiation. 
 
Drain line and “Drain Connector” 
must be removed prior to bowl and 
float drain removal. 

 

Drain Timer Factory Preset  

4 seconds 

on time 

10 minutes 

off time 

 

The factory setting is applicable for virtually all 
industrial applications. If adjustment is required 
contact your local distributor for alternate settings 
and procedures. 

Condensate discharged from the dryer may contain oil/lubricants. 

Verify and follow local regulations regarding disposal. 

 

 

 

Содержание GSRN Series

Страница 1: ...NG STANDARD Contents Introduction Page 2 General Safety Warnings Page 2 Proper Use of the Dryer Page 3 Receiving Equipment Page 3 Installation Location and Piping Page 3 Recommended System Design Page...

Страница 2: ...00 682 9868 Failure to install the compressed air dryer per this manual or any change to the dryer not previously authorized by the manufacture will void the warranty The information and specification...

Страница 3: ...be located on a level floor or shelf free from vibrations and sufficient to support the total weight of the machinery Although the dryer package is a freestanding unit it may be secured by bolting th...

Страница 4: ...100 F 37 7 C 105 F 40 5 C 110 F 43 3 C 115 F 46 1 C 120 F 48 8 C Additional Load 0 15 32 51 75 The pipe connection to the dryer should match the standard connection ports provided The chart below is p...

Страница 5: ...ssembly GSRN 50 through GSRN 2250 When maintaining float drains depressurize the dryer drain prior to work initiation Drain line and Drain Connector must be removed prior to bowl and float drain remov...

Страница 6: ...0 PSIG for two fan units If the suction analyzer or discharge gauge is not in the specified range contact your local distributor GSRN 100W through GSRN 200W The water cooled series GSRN 100W through G...

Страница 7: ...y discharging condensate and air from the drain tube try replacing the solenoid valve diaphragm or the complete drain valve As Required MODEL CAPACITY CORRECTION MULTIPLIER Inlet Temp 90 F 100 F 110 F...

Страница 8: ...rize dryer and replace or clean drain strainer 2 Solenoid valve or electronic timer failure Replace drain solenoid and or timer assembly C Drain System Failure with continuous condensate or air discha...

Страница 9: ...1200 1500 1750 2000 2250 Min Max Inlet Pressure 30 PSIG 2 1 kgf cm 220 PSIG 30 PSIG 2 1 kgf cm 150 PSIG 10 6 kgf cm Max Inlet Temperature 120 F 48 8 C Min Max Ambient Temperature 50 F 10 C 110 F 43 3...

Страница 10: ...to investigate and inspect any assumed defects At seller s option buyer must return any defective materials to seller s plant or authorized depot at buyer s expense Freight charges for returned or rep...