background image

HYD-7-610  

EN-7

EN

SYNTHETIC COMPRESSOR LUBRICANT MATERIAL COMPATIBILITY 

LIST

COMPATIBILITY LIST SUITABLE :

FKM (Fluoroclastomer), PTFE, Epoxy (Glass Filled), Oil Resistant Alkyd, 

Fluorosilicone, Fluorocarbon, Polysulfide, 2-Component Urethane, 

Nylon, POM (Polyoxymethylene/Polyacctel), High Nitrile Rubber (Buna 

N. NBR more than 36% Acrylonitrile), Polyurethane, Polyethylene, 

Epichlorohydrin, Polyacrylate, Melamine, Polypropylene, Baked 

Phenolics, Epoxcy, Modified Alkyds (® indicates trademark of DuPont 

Corporation).

 

NOT RECOMMENDED :

Neoprene, Natural Rubber, SBR Rubber, Acrylic Paint, Lacquer, Varnish, 

Polystyrene, PVC, ABS, Polycarbonate, Cellulose Acetate, Low Nitrile 

Rubber (Buna N. NBR less than 36% Acrylonitrile), EPDM, Ethylene Vinyl 

Acetate, Latex, EPR, Acrylics, Phenoxy, Polysulfones, Styrene Acrylonitrile 

(San), Butyl.

 

„

GENERAL REQUIREMENTS 

The piping, fittings, air receiver tank, etc. must be certified safe for at least 

the maximum working pressure of the unit. Use hard-welded or threaded 

steel or copper pipes and cast iron fittings that are certified safe for the 

unit’s discharge pressure and temperature. DO NOT USE PVC PLASTIC. Use 

pipe thread sealant on all threads, and make up joints tightly to prevent air 

leaks.

 

„

DRIVE OPTIONS

• 

DIRECT DRIVE

A 1100 series flange is available to direct drive the GD 70. The following 

guidelines should be followed:

 • Compressor shaft and PTO shaft should be parallel within 2 degrees.
 • Maximum compound drive angle must be no greater than 11 degrees.
 • Install a “U” bolt hanger for safety in case of a driveshaft failure.

• 

HYDRUALIC DRIVE

If the unit is to be driven by hydraulic motor, the shafts must be aligned as 

follows:

 • Shaft offset of no more than 0.015”.
 • Shafts parallel within 1 degree.

 

„

COMPRESSOR LUBRICATION

CAUTION

Do not operate without lubricant or with inadequate lubricant. 

Gardner Denver is not responsible for compressor failure caused 

by inadequate lubrication.

 

„

SYNTHETIC COMPRESSOR LUBRICANT 

We recommend AEON AC-SY compressor lubricant from start-up. See the 

WARRANTY section for extended warranty information. 

 

„

ALTERNATE LUBRICANTS 

You may use AEON AC-HC or a comparable petroleum-based lubricant that 

is premium quality, does not contain detergents, contains only anti-rust, 

anti-oxidation, and anti-foam agents as additives, has a flashpoint of 440°F 

(227°C) or higher, and has an auto-ignition point of 650°F (343°C) or higher.

See the petroleum lubricant viscosity table below. The table is intended 

as a general guide only. Heavy duty operating conditions require heavier 

viscosities. Refer specific operating conditions to 

Gardner Denver

 for 

recommendations.

Temperature 

Around Compressor

Viscosity at 100

°

F

(37.8 

°

C)

Viscosity Grade

°F

°C

SUS

Centistokes

ISO

SAE

40 & 

below

4.4 & 

below

150

32

32

10

 40-80

4.4-26.7

500

110

100

30

   80-125

26.7-51.0

750

165

150

40

Содержание GD 70

Страница 1: ...Parts List Operating Service Manual GD 70 COMPRESSOR HYD 7 610 Version 00 February 26 2021 Models GD 70...

Страница 2: ...CIRCUIT 6 INSTALLING REMOTE AIR INLET PIPING 6 INSTALLING DISCHARGE PIPING 6 GENERAL REQUIREMENTS 7 DRIVE OPTIONS 7 COMPRESSOR LUBRICATION 7 SYNTHETIC COMPRESSOR LUBRICANT 7 ALTERNATE LUBRICANTS 7 FIL...

Страница 3: ...lete inventory of new machines and new genuine factory parts 3 A full line of factory tested AEON lubricants specifically formulated for optimum performance in all compressors 4 Authorized distributor...

Страница 4: ...sed air should not be used for breathing air applications unless treated in accordance with all applicable codes and regulations WARNING Moving parts Can cause serious injury Do not operate with guard...

Страница 5: ...ly contact the carrier for an inspection All material must be held in the receiving location for the carrier s inspection Delivery receipts that have been signed without a notation of damage or missin...

Страница 6: ...G Remove the unit from the skid before mounting The unit must be permanently mounted When mounting the unit bolt the feet to a firm level foundation TYPICAL DISCHARGE CIRCUIT Discharge piping should i...

Страница 7: ...owing guidelines should be followed Compressor shaft and PTO shaft should be parallel within 2 degrees Maximum compound drive angle must be no greater than 11 degrees Install a U bolt hanger for safet...

Страница 8: ...e thoroughly decarbonized and the crankcase must be flushed before conversion FILLING PROCEDURES 1 Unscrew and remove the oil fill plug A 2 Slowly fill the crankcase with lubricant until thelubricant...

Страница 9: ...compressor lubricant and 60 continuous duty operation with the use of petroleum lubricant In other words synthetic lubricant allows the compressor to pump continuously without cycling Petroleum lubri...

Страница 10: ...ect air filter element s Clean or replace if necessary Monthly Inspect for air leaks Squirt soapy water around joints during compressor operation and watch for bubbles Check tightness of screws and bo...

Страница 11: ...does not come up to speed Lubricant viscosity too high Drain existing lubricant and refill with proper lubricant Compressor valves leaky broken carbonized or loose Inspect valves Clean or replace as...

Страница 12: ...bearings worn or scored Inspect all Repair or replace as required Defective ball bearings on crankshaft or motor shaft Inspect bearings and replace crankshaft assembly if required Moisture in crankca...

Страница 13: ...HYD 7 610 EN 13 EN PARTS LIST GD70...

Страница 14: ...04 lWASHER 1 17 96730437 lCAPSCREW M8 X 20 LEFT HAND THREAD 1 17A 95245494 lKEY WOODRUFF 18 97334254 ASSEMBLY OIL FILL PLUG 1 19 NSS lPLUG OIL FILL 1 20 97334288 lO RING OIL FILL PLUG 1 21 97333389 AS...

Страница 15: ...SIGHT 1 45 54410683 HEAD 1 46 70243936 ASSEMBLY VENT 1 o 47 P04999A FILTER INLET SEE PAGE 17 FOR REPLACEMENT ELEMENT 1 o 48 64U1 ELBOW PIPE 1 NSS NOT SOLD SEPARATELY AVAILABLE lNDlVlDUALLY OR IN VALVE...

Страница 16: ...s AIR FILTER ELEMENT Part No Description P05050A Element Air Filter REPAIR KITS Repair kits provide all of the parts required to perform common repair tasks such as piston ring replacement or valve re...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...er Denver Inc 1800 Gardner Expressway Quincy IL 62305 Customer Service Department Telephone 800 682 9868 pd bloweers gardnerdenver com www gardnerdenverproducts com 2021 Gardner Denver Inc Printed in...

Отзывы: