background image

 EN-4                                                                                                                                                                                                               HYD-7-610

EN

DANGER

Indicates an imminently hazardous 

situation which, if not avoided, will result 

in death or serious injury.

WARNING

Indicates a potentially hazardous situation 

which, if not avoided, could result in death 

or serious injury.

CAUTION

Indicates a potentially hazardous situation 

which, if not avoided, may result in minor 

or moderate injury or property damage.

NOTICE

Indicates information or a company 

policy that relates directly or indirectly to 

the safety of personnel or protection of 

property.

 

„

GENERAL SAFETY PRECAUTIONS 

DANGER

Intake air can contain carbon monoxide or other contaminants. 

Will cause serious injury or death. Gardner Denver air 

compressors are not designed, intended or approved for 

breathing air. Compressed air should not be used for breathing 

air applications unless treated in accordance with all applicable 

codes and regulations.

WARNING

Moving parts. Can cause serious injury. Do not operate with 

guards removed. 

Hot surfaces. Can cause serious injury. Do not touch. Allow to 

cool before servicing. Do not touch hot compressor or tubing.

High pressure air. Bypassing, modifying or removing safety/relief 

valves can cause serious injury or death. Do not bypass, modify 

or remove safety/relief valves. Do not direct air stream at body. 

CAUTION

A caution risk of bursting. Use only suitable air handling parts 

acceptable for pressure of not less than the maximum allowable 

working pressure of the machine.

SAFETY

GENERAL INFORMATION

Your air compressor is suitable for the Transport Market used to assist with 

liquid bulk tanker offload. The following accessories may be required:

 • Relief valve
 •  Check valve
 • Hot pressure hose
 •  3-way ball valve
 • Pressure gauge.

Содержание GD 70

Страница 1: ...Parts List Operating Service Manual GD 70 COMPRESSOR HYD 7 610 Version 00 February 26 2021 Models GD 70...

Страница 2: ...CIRCUIT 6 INSTALLING REMOTE AIR INLET PIPING 6 INSTALLING DISCHARGE PIPING 6 GENERAL REQUIREMENTS 7 DRIVE OPTIONS 7 COMPRESSOR LUBRICATION 7 SYNTHETIC COMPRESSOR LUBRICANT 7 ALTERNATE LUBRICANTS 7 FIL...

Страница 3: ...lete inventory of new machines and new genuine factory parts 3 A full line of factory tested AEON lubricants specifically formulated for optimum performance in all compressors 4 Authorized distributor...

Страница 4: ...sed air should not be used for breathing air applications unless treated in accordance with all applicable codes and regulations WARNING Moving parts Can cause serious injury Do not operate with guard...

Страница 5: ...ly contact the carrier for an inspection All material must be held in the receiving location for the carrier s inspection Delivery receipts that have been signed without a notation of damage or missin...

Страница 6: ...G Remove the unit from the skid before mounting The unit must be permanently mounted When mounting the unit bolt the feet to a firm level foundation TYPICAL DISCHARGE CIRCUIT Discharge piping should i...

Страница 7: ...owing guidelines should be followed Compressor shaft and PTO shaft should be parallel within 2 degrees Maximum compound drive angle must be no greater than 11 degrees Install a U bolt hanger for safet...

Страница 8: ...e thoroughly decarbonized and the crankcase must be flushed before conversion FILLING PROCEDURES 1 Unscrew and remove the oil fill plug A 2 Slowly fill the crankcase with lubricant until thelubricant...

Страница 9: ...compressor lubricant and 60 continuous duty operation with the use of petroleum lubricant In other words synthetic lubricant allows the compressor to pump continuously without cycling Petroleum lubri...

Страница 10: ...ect air filter element s Clean or replace if necessary Monthly Inspect for air leaks Squirt soapy water around joints during compressor operation and watch for bubbles Check tightness of screws and bo...

Страница 11: ...does not come up to speed Lubricant viscosity too high Drain existing lubricant and refill with proper lubricant Compressor valves leaky broken carbonized or loose Inspect valves Clean or replace as...

Страница 12: ...bearings worn or scored Inspect all Repair or replace as required Defective ball bearings on crankshaft or motor shaft Inspect bearings and replace crankshaft assembly if required Moisture in crankca...

Страница 13: ...HYD 7 610 EN 13 EN PARTS LIST GD70...

Страница 14: ...04 lWASHER 1 17 96730437 lCAPSCREW M8 X 20 LEFT HAND THREAD 1 17A 95245494 lKEY WOODRUFF 18 97334254 ASSEMBLY OIL FILL PLUG 1 19 NSS lPLUG OIL FILL 1 20 97334288 lO RING OIL FILL PLUG 1 21 97333389 AS...

Страница 15: ...SIGHT 1 45 54410683 HEAD 1 46 70243936 ASSEMBLY VENT 1 o 47 P04999A FILTER INLET SEE PAGE 17 FOR REPLACEMENT ELEMENT 1 o 48 64U1 ELBOW PIPE 1 NSS NOT SOLD SEPARATELY AVAILABLE lNDlVlDUALLY OR IN VALVE...

Страница 16: ...s AIR FILTER ELEMENT Part No Description P05050A Element Air Filter REPAIR KITS Repair kits provide all of the parts required to perform common repair tasks such as piston ring replacement or valve re...

Страница 17: ......

Страница 18: ......

Страница 19: ......

Страница 20: ...er Denver Inc 1800 Gardner Expressway Quincy IL 62305 Customer Service Department Telephone 800 682 9868 pd bloweers gardnerdenver com www gardnerdenverproducts com 2021 Gardner Denver Inc Printed in...

Отзывы: