SB-7-621 Page 20
SECTION 4
OPERATION
Future operating problems can be avoided if proper precautions are observed when the equipment is first put into
service.
Before starting under power, the blower should be turned over by hand to make certain there is not binding or
internal contact.
Each size blower has limits on pressure differential, running speed and discharge temperature which must not be
exceeded. These limits are shown in “Maximum Operating Limitations”, FIGURE 4-1, below.
Operating beyond the specified operating limitations will result in damage to the unit.
It is important that the pressures and temperatures are measured directly at the ports of the blower to avoid error
that may be caused by intervening pipe runs, fittings, etc.
Relief valves must be used to protect against excessive pressure or vacuum conditions. These valves should be
tested at initial startup to be sure they are adjusted to relieve at or below the maximum pressure differential rating
of the blower.
NOTICE
Relief valves should be placed as close as possible to the blower inlet or discharge.
In some instances, pressure may be relieved at a lower point than the blower maximum in order to protect the
motor or the equipment served by the blower.
Discharge temperature switches are recommended to protect against excessive inlet restriction or inlet
temperatures. Check valves in the discharge line on pressure blowers and in the inlet line on vacuum blowers are
recommended to protect the blower from motoring backwards when shut down under load.
LIMITATIONS
For information regarding limitations, refer to FIGURE 4-1, below.
MAXIMUM OPERATING LIMITATIONS
SIZE
RPM
PRESSURE
PSI
VAC
IN HG
DISCHARGE
TEMPERATURE ° F
2LP
5275
7
14
285
2MP
5275
12
15
315
3LP
3600
7
14
260
3MP
3600
12
15
280
3HP
3600
15
16
320
4LP
3600
7
14
260
4MP
3600
10
16
285
4HP
3600
15
16
310
5LP
2850
7
14
260
5MP
2850
13
16
280
5HP
2850
15
16
300
DO NOT EXCEED THESE LIMITS
NOTICE
Blower speed, line losses, elevation, and increased inlet temperatures will affect the
maximum operating limitations.
FIGURE 4-1 – MAXIMUM OPERATING LIMITATIONS
Содержание GAA_ _ P Series
Страница 2: ......
Страница 36: ...SB 7 621 Page 35 SECTION 8 PARTS LIST 300GAA810 C Ref Drawing ...
Страница 38: ...SB 7 621 Page 37 200GAB810 E Ref Drawing ...
Страница 40: ...SB 7 621 Page 39 300GAC810 B Ref Drawing ...
Страница 42: ...SB 7 621 Page 41 300GAC810 B Ref Drawing ...
Страница 44: ...SB 7 621 Page 43 ...