Installation
5.3 Connecting pipes
WARNING
Sealing or constricting of the exhaust air outlet
(Fig. 2/B) may lead to severe or fatal injuries!
In the aggregate an inside pressure can be higher
and higher, which leads to the destruction of com-
ponents!
NOTICE
Material damage resulting from the forces and
torques of the pipes on the unit being too high.
Only screw pipes in by hand.
The suction capacity of the vacuum pump is
reduced if the suction pipe is too narrow and/
or too long.
Counter pressures on the outlet side are only
permissible up to + 0.1 bar.
Prevent liquids accumulating in the exhaust
line.
a) The vacuum connection (Fig. 2/A) can be found
on the suction flange (Fig. 2/D).
b) The discharged air can be freely blown out
through the exhaust air hole (Fig. 2/B) or con-
ducted away using a hose or pipe.
5.4 Filling with lubricating oil
a) Fill the lubricating oil (for suitable types see the
“Maintenance” section) via the oil filling point
(Fig. 2/H) up to the upper edge of the sight glass
(Fig. 2/I).
b) Close the oil filling points.