27
www.gd-elmorietschle.com
© Gardner Denver Schopfheim GmbH
|
Maintenance and repair
Fig. 9 Intake filter
f
2
m
2
g
2
1
Compressed air
f
2
Filter cartridge
g
2
Filter cover
m
2
Brackets
1
f
2
a) Take off the inlet flange (Fig. 8/D) after releasing the screws (Fig. 8/s
1
).
b) Clean the mesh filter (Fig. 8/f
1
).
Also check the valve seat for contamination.
Re-assemble in reverse order.
Intake filter (accessories)
Clean the filter cartridge of the intake filter every month or more often, depending on pollution, by blowing
off from the inside to the outside.
In spite of cleaning the filter its separation efficiency will continue to deteriorate. Therefore the filter should
be replaced every six months.
a) Release the brackets (Fig. 9/m
2
) on the filter cover (Fig. 9/g
2
).
b) Remove the filter cartridge (Fig. 9/f
2
) from the filter and clean or replace.
c) Re-insert the filter cartridge in the filter and fasten the filter cover (Fig. 9/g
2
) with the brackets (Fig. 9/m
2
).