13–9/10–641 Page 19
FIGURE 4–1 – SCHEMATIC TUBING DIAGRAM
211ECM797–B
(Ref. Drawing)
Blowdown Valve (FIGURE 4–2) – This valve normal-
ly is used for control functions, but also serves to relieve
reservoir pressure following a shutdown. The blow-
down valve is a two–way solenoid valve which is piped
into the oil reservoir outlet ahead of the minimum pres-
sure valve. When the solenoid is de–energized, the
valve opens and the coolant system is blown down.
When the solenoid is energized, the valve closes to al-
low the coolant system to pressurize. A control air
check valve is provided to ensure that the inlet valve is
closed during blowdown.
Oil Level Gauge (FIGURE 1–6, Section 1, page 3) –
This gauge is located on the oil reservoir and indicates
the oil level. See section 5 for information on how to
correctly read the gauge and proper lubrication.
Minimum Discharge Pressure/Check Valve
(FIGURE 4–3, page 20) – An internal spring–loaded
minimum pressure valve is used in the final discharge
line to provide a positive pressure on the coolant sys-
tem of the compressor even if the air service valve is
fully open to atmospheric pressure. This valve also
functions as a check valve to prevent back flow of air
from the shop air line when the unit stops, unloads, or
is shut down.
FIGURE 4–2 – BLOWDOWN VALVE
Содержание ELECTRA-SAVER II
Страница 15: ...13 9 10 641 Page 6 DECALS 206EAQ077 212EAQ077 218EAQ077 211EAQ077 207EAQ077...
Страница 16: ...13 9 10 641 Page 7 DECALS 216EAQ077 217EAQ077 222EAQ077 221EAQ077 208EAQ077...
Страница 39: ...13 9 10 641 Page 30 FIGURE 4 13 WIRING DIAGRAM 207ECP546 WYE DELTA EBH EBM EBP UNITS WITH ES CONTROLS...
Страница 40: ...13 9 10 641 Page 31 FIGURE 4 14 WIRING DIAGRAM 209ECP546 FULL VOLTAGE EBH EBM EBP UNITS WITH ES CONTROLS...
Страница 43: ...13 9 10 641 Page 34 FIGURE 5 1 FLOW DIAGRAM AIR OIL SYSTEM TURN VALVE UNITS 221ECM797 B Ref Drawing...
Страница 62: ......