2.1 For Your Safety

1)  Use extreme caution when checking electrical circuits.

2)

Do not stand in wet or damp work areas when

working with electricity. Wear rubber-soled boots or shoes.

3) 

Do not apply more voltage or current

than the set range of the meter will allow.

4) 

Do not touch the metal probes of the test

leads when making a measurement.

5)  Replace worn test leads. Do not use test leads with

broken or tattered insulation.

6)  Discharge a capacitor before measuring it.

7)  Remove the test leads from the circuit being measured as

soon as the test is completed.

8) 

Do not measure voltage when the

function/range switch is set on the resistance (ohms) range.
Never measure current when the meter is set on the
resistance range. Never measure AC voltage when the
meter is set on DC voltage. Setting the meter on the
incorrect function may burn out some of the internal circuitry
and may pose a safety hazard.

3. Operating Suggestions

1)  Set the function/range switch to the proper position before

making a measurement. When the voltage or current is
not known, it MUST be determined that the capacity of the
selected range will handle the amount of voltage or current
in the circuit (see #3 under For Your Safety). Always start
with the highest range in the function. If the reading falls
within the range of a lower setting, reset the function/range
switch to the appropriate setting for greater accuracy.

2) Avoid placing the meter in areas where vibration, dust or

dirt are present. Do not store the meter in excessively hot,
humid or damp places. This meter is a sensitive
measuring device and should be treated with the same
regard as other electrical and electronic devices.

3)  Using the meter in areas with high magnetic fields can

result in inaccurate readings. For greatest accuracy, lay
the meter flat on a non-metallic surface.

4

!

WARNING

!

WARNING

!

WARNING

!

WARNING

2. Specifications

Ranges: 

8 measuring ranges

DC Voltage: 

60 Volts

AC Voltage: 

60-300-600 Volts

AC Current: 

6-60-600 Amps

Resistance (Ohms):

1K OHM

Accuracy: 

DC voltage = 4% full scale of range
AC voltage = 5% full scale of range
AC current = 5% full scale of range
Resistance = 4° arc of scale length

Sensitivity: 

2300 OHMS per AC Volt, 2500 OHMS per DC Volt

Function/Range switch: 

4 functions
8 positions

Zero Ohms Adjustment Dial:  Located on the right side of the housing; 

dial is used to zero the needle indicator on the 
ohms scale while shorting the test leads together.

Mechanical Zero 
Adjustment Screw:

Adjusts needle indicator to read zero 
at the left side of the scale before taking 
any measurement.

Recessed Input Jacks: 

Negative (-) input jack for black test lead, positive 
(+) input jack for red test lead.

Fuse:

.5 Amp/250 Volt

Battery:

One “AA”

Important:

Read this operators manual thoroughly before using this
multimeter. This manual is intended to provide basic
information regarding this meter and to describe common test
procedures which can be made with this unit. Many types of
appliance, machinery and other electrical circuit
measurements are not addressed in this manual and should
be handled by experienced service technicians.

Use extreme caution when using this

meter. Improper use of this meter can result in severe
damage to property, severe personal injury or death.
Follow all instructions and suggestions in this operators
manual as well as observing normal electrical safety
precautions. Do not use this meter if you are unfamiliar
with electrical circuits and proper test procedures. 

3

!

WARNING

Содержание Instruments GCM-500

Страница 1: ...nual thoroughly before use and save Lea atentamente este manual del propietario antes de utilizar y guardar Lisez ce manuel enti rement avant utilisation et rangez le soigneusement Gardner Bender COM...

Страница 2: ...Functions Needle Analog Scale Zero Ohms Adjustment Dial Input Jacks Function Range Selector Switch Contents 1 Meter Functions 2 Specifications 2 1 For Your Safety 3 Operating Suggestions 3 1 Measurin...

Страница 3: ...as other electrical and electronic devices 3 Using the meter in areas with high magnetic fields can result in inaccurate readings For greatest accuracy lay the meter flat on a non metallic surface 4...

Страница 4: ...The jaws are only used for taking amperage readings 3 1 Measuring Resistance Before making resistance or continuity tests check the condition of the internal battery First turn the function range swit...

Страница 5: ...te the back cover from the front 2 Note the polarity of the battery when removing it from its compartment and replace 3 Use GB catalog number GF 0306 0 5A 250V replacement fuses 4 Carefully replace th...

Страница 6: ...Marcador a Cero Ohmios Clavijas de entrada Interruptor Selector de Funci n Rango Figura 1 Cubierta de las Pilas Fusible Tornillo de Ajuste Mec nico a Cero Contenidos 1 Funciones del Pol metro 2 Espec...

Страница 7: ...VERTENCIA ADVERTENCIA ADVERTENCIA ADVERTENCIA ADVERTENCIA ADVERTENCIA 2 Especificaciones Rangos 8 rangos de medici n Voltaje CC 60 Voltios Voltaje CA 60 300 600 Voltios Intensidad CA 6 60 600 Amperios...

Страница 8: ...pol metro es un dispositivo de medida sensible y se ha de tratar con los mismos cuidados que el resto de los dispositivos electr nicos 3 Si se utiliza el pol metro en zonas con campos magn ticos fuer...

Страница 9: ...ontal 2 Observe la polaridad de la bater a cuando la retire de su compartimento y cuando la recambie 3 Utilice el n mero de cat logo GF 0306 0 5 A 250 V para el cambio de los fusibles 4 Vuelva a coloc...

Страница 10: ...de R glage Z ro Ohms Jacks d entr e S lecteur de Fonctions Gammes Figure 1 Couvercle de Pile Fusible Vis de r glage du Z ro M canique Table des mati res 1 Fonctions du multim tre 2 Caract ristiques 2...

Страница 11: ...SEMENT AVERTISSEMENT AVERTISSEMENT AVERTISSEMENT AVERTISSEMENT 2 Caract ristiques Gammes 8 gammes de mesure Tension continue 60 Volts Tension alternative 60 300 600 Volts Courant Alternatif 6 60 600 A...

Страница 12: ...multim tre dans des lieux avec des vibrations de la poussi re ou de la salet Ne rangez pas le multim tre dans des endroits o la chaleur ou l humidit est excessive Ce multim tre est un appareil de mes...

Страница 13: ...la partie avant 2 Notez la polarit de la pile lorsque vous la retirez de son logement et remplacez la 3 Utilisez les fusibles de rechange du catalogue GB num ro GF 0306 0 5A 250V 4 R installez pr caut...

Отзывы: