background image

Instructions Continued

Pump Operation

PE22J/PE24J

Start the unit using the 3 position toggle switch
located in the shroud.
Regular:

Switch up

is for continuous

operation;

Switch down

is for 

jogging operation;

Off

is in the 

center position.

Remote Jog

with a remote control jog pendant
station:

Switch up

is for continuous

operation;

Switch down

is for 

remote jogging;

Off

is in the

center position.

Hushh-Pumps (PE34J/PE34R)

1. Make sure all hose connections are tight and

the power cord is connected properly.

2. Turn air vent screw counterclockwise 2 or 3 turns.
3. Push motor switch to "On" position.
4. Let pump idle for a few minutes.
5. To advance plunger, press the "advance" button

on the push-button station. For manual valves,
place valve in "advance" position.

6. To retract plunger, press the "retract" button on

the push-button station. For manual valves, place
the valve in "retract" position.

NOTE

: For operation and control of 3 and 4-way

valves, see valve instruction sheet.

Removal of Air

The hydraulic system, when connected for the first
time, will have air in the system. The air must be
removed for safety and proper operation. Air can
generally be removed from the system by fully
advancing and retracting the hydraulic cylinder 

several times. When the trapped air is removed from
the hydraulic circuit, the cylinders will advance and
retract smoothly. Sluggish cylinder action is usually
the first sign of air in the system.

WARNING:

Do not exceed cylinder 
capacity or stroke.

Adjusting Relief Valve

PE22J/PE24J

1. Gauge adaptor, gauge, and shut-off valve must

be installed in the system between pump and
cylinder. Remove the air vent.

2. Start motor. Purge air from the system.
3. Press the advance button or place the manual

valve in advance.

4. Insert 

7

32

" Allen wrench through hole and into

adjusting screw.

5. Turn adjusting screw to obtain desired pressure

(or load) reading on gauge:

Counterclockwise

to 

reduce

gauge reading;

Clockwise

to 

increase

gauge reading.

WARNING

: Do not exceed the pump

operating pressure.

6. Check valve setting by operating the valve

several times in the advance and retract
positions. Maximum gauge reading should
remain constant.

Hushh Pumps (PE34J/PE34R)

1. Remove flush pipe plug from side of reservoir.
2. Insert 

5

16

" Allen wrench into adjusting screw.

3. Turn adjusting screw to obtain desired pressure

(or load) reading on gauge.

Air Vent

Remove 
to access
relief valve