background image

11

10

“On” position

In the 

On

position the valve is opened after a delay of 2 seconds and then

automatically closed again after 30 minutes. If the water timer is switched
to 

On

during an automatic watering program the valve stays open and is

closed after 30 minutes.

“Off” position

In the 

Off

position, an open valve is closed after a delay of 2 seconds.

10. Changing the Setting

The time and the watering time can be changed using the control knob

(Run Time).

The changes are accepted after approx. 5 seconds and this is signalled
acoustically by a double beep. If the water timer is not reset the original
starting time remains unchanged.

Making changes during watering 

You can change the watering time 

(Run Time)

during an automatic 

watering program as follows:

.

If the elapsed watering time is 

shorter

than the new watering time 

you have selected, 

then the new watering time is valid.

Example :

Old 

Run Time

= 10 minutes, changed after 5 minutes to 30 minutes.

The total watering time is then 30 minutes.

.

If the watering time which has already expired is 

longer

than the new

watering time, the water flow is interrupted in the next minute.

If you have already chosen the

starting time (Start Time / Run Time

already set) any changes you make to the watering frequency 

(Frequency) 

are active as soon as the next watering program starts.

If you have forgotten the current start time, you should reset the Water
Timer and then re-enter the watering data.

9.3  Examples

Current time: 9:00 am.

The watering program should run as follows:

Example a)

Every day at 9:00 for 10 minutes.

Example b)

3 x a day (= every 8 hours) for 2 minutes. at 10:00, 
at 18:00 and at 2:00.

Example c)

Every 3 days at 16:00 for 60 minutes.

The timer should be programmed as follows:

Step 1

Step 2

Step 3

Setting

Setting

Start Time 

Frequency

Run Time

key

Example a)

24 h

10 min.

do not press

Example b)

8 h

2 min.

press once

Example c)

3

rd

60 min.

press 7 times

The watering time has now been changed. The water timer will now 
automatically run the required watering programs.

9.4  Turning off the watering programs

The watering programs can be switched off for any period of time 
e.g. in periods of bad weather as follows:

1. Turn the 

Run Time

knob 

3

clockwise to 

Off.

2. To restart the watering e.g. at the end of the bad weather period, 

turn the 

Run Time

knob 

3

back to the required watering time.

Note :

The starting time you previously selected remains unchanged 

so that your garden is watered at the usual times (the times you pro-
grammed).

9.5  Manual On / Off operation

In addition to watering your garden fully automatically, the Water Timer 
can be operated manually by turning the 

Run Time

knob 

3

to 

On

or 

Off.

Automatic watering programs during this time are not executed or inter-
rupted. After manually opening / closing the valve 

(On / Off)

you can once

again select a watering time. A watering starting time which you deter-
mined earlier remains unchanged.

Содержание T 1030 1805

Страница 1: ...ronic T 1030 S Bruksanvisning Bevattningstimer electronic T 1030 NL Gebruiksaanwijzing Elektronische watertimer T 1030 D Gebrauchsanweisung Bew sserungsuhr electronic T 1030 FIN K ytt ohjeet Elektroni...

Страница 2: ......

Страница 3: ...are on holiday 4 GARDENA Water Timer Electronic T 1030 1 Notes on these Operating Instructions Please read these operating instructions carefully and observe the notes given Use these operating instru...

Страница 4: ...y markings 2 Setting the watering frequency The following watering cycles can be selected using the Frequency control knob 3 Setting the watering time starting time Run Time You can select the waterin...

Страница 5: ...y active for a max of 5 seconds after the last time you press the key It is then no longer possible to change the starting time This is signalled by a double beep The watering starting time can only b...

Страница 6: ...e current start time you should reset the Water Timer and then re enter the watering data 9 3 Examples Current time 9 00 am The watering program should run as follows Example a Every day at 9 00 for 1...

Страница 7: ...before the frosty season begins The max temperature for the water flow is 40 C The minimum operating pressure is 1 bar the maximum opera ting pressure is 12 bar For functional safety reasons only use...

Страница 8: ...ENA Soil Moisture Sensor Fig E Together with the GARDENA Soil Moisture Sensor Art No 1187 watering is controlled considering the soil moisture Assembly The Soil Moisture Sensor is connected to the soc...

Страница 9: ...es EU Certificate of Conformity The undersigned GARDENA Kress Kastner GmbH Hans Lorenser Str 40 D 89079 Ulm hereby certifies that when leaving our factory the unit indicated below is in accordance wit...

Страница 10: ...se contact our Customer Service or return the defective unit together with a short description of the problem directly to one of the GARDENA Service Centres listed on the back of this leaflet S Garant...

Страница 11: ...tca 22 1158 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S r l Via D...