10
GB
The pump must not be operated when there
are people in the water. Swimming pools and
garden ponds should be designed according to
international and national design regulations.
v
Please consult a professional electrician.
For Austria :
Pumps for use on swimming pools and on
ponds may only be operated via an isolating
transformer.
v
Please consult a professional electrician.
For Switzerland :
In Switzerland mobile appliances which are
used outdoors, must be connected via a resi-
dual-current device.
Note :
Do not allow the pump to run without water
because dry-running leads to an undesira-
ble build up of heat.
Before operating the pump, look to see if there
is any damage to the pump (esp. regarding
power cable and plug). The connection cable
of the pump cannot be replaced. If the cable is
damaged the pump must be scrapped. Ensure
that the power cable cannot be crushed if it
has not been laid in conduit in the earth or in
gravel.
Do not use the power cable to carry the pump
or to pull the plug out of the socket.
Protect the power cable from heat, oil and
sharp edges.
The temperature of the liquid used must not
be below 4 °C or above 35 °C.
Sand and other abrasive substances in the
liquid cause increased wear and reduce the
output of the pump.
Please observe the local noise prevention
regulations.
All pumps
(a cascade
art. 7650
(b Waterbell
- 7654
(c jets of
water
art. 7655 - 7657
(d foaming -
spring
3. Assembly
To provide a firmer mounting, the filter housing can be attached to
a solid base (e.g. paving stone).
1. Screw nozzle pipe
1
on to the pump with the ball and socket
joint.
2. Screw the water feature insert you require
(a
/
(b
/
(c
/
(d
on
the nozzle pipe
1
.
2
Holder for
GARDENA underwater light art 7951
The additional filter can be fitted on the filter housing to extend the
maintenance interval and to give the water feature a longer life.
1. Remove the cap
3
from the pump.
2. Fit both filter shells
4
on the filter housing
5
and clip into
place.
3. Press sealing cover
3
on to the additional filter
4
.
You can install additional filters
z
4a
to increase the filter surface.
Additional filters are available from GARDENA Service.
Fit the pump :
VARIANT 1 : Mount the
additional filter on the pump :
2
1
5
3
4
z
4a