12
GB
Fault Possible
cause
Remedy
Watering is not switched on
Valve has been closed manually.
v
Turn Run Time button to a
although soil is dry
watering duration.
The control panel has not been
v
Insert control panel
inserted correctly.
correctly.
Watering is switched on
Soil Moisture Sensor not
v
Position Soil Moisture
although soil is damp
positioned in watering area.
Sensor in watering area.
Switching controller too far
v
Turn switching controller to
to the right on “Damp”.
the left accordingly.
Defective or loose sensor cable.
v
Check sensor cable and
connections.
Air trapped at sensor tip.
v
Remove trapped air (see
4. Initial Operation
“ “Plant”
Soil Moisture Sensor ” ).
Automatic Irrigation Set
Minimum flow rate below
v
Connect more drip heads.
does not close
below 20 l / h.
Battery display of Soil
Batteries of Soil Moisture
v
Replace batteries ofSoil
Moisture Sensor flashing
Sensor spent / inserted Moisture
Sensor / insert
incorrectly / wrong batteries
correctly / use alkaline
used.
batteries.
Soil Moisture Sensor defective.
v
Contact GARDENA Service.
Error indicator of
Batteries of Soil Moisture
v
Replace batteries ofSoil -
Water Timer flashing
Sensor spent / inserted Moisture
Sensor / insert
incorrectly / wrong battery
correctly / use alkaline
used.
battery.
Batteries of Soil Moisture Sensor
v
Replace batteries of Soil
are flat.
Moisture Sensor.
Cable of Soil Moisture Sensor
v
Replace cable of Soil
defective.
Moisture Sensor.
Defective or loose sensor cable.
v
Check sensor cable and
connections.
A
In the event of other faults please contact GARDENA Service.
Repairs should only be carried out by GARDENA service centres or dealers
authorised by GARDENA.
9. Accessories
GARDENA Extension Cable
Used to extend sensor cable to
Art. 1186
(length : 10 metres)
max. 105 metres.
GARDENA sensor tip
For replacement of damaged
Obtainable via
with felt
sensor tip.
GARDENA Service