Warning ! Electric shock !

Risk of injury due to electric shock.

Always unplug your Garden Pump before
filling, after operation, when trouble-
shooting and before carrying out any 
maintenance work.

Hot water – 
risk of scalding !

If the pump is operated for prolonged peri-
ods of time (> 5 min) with the delivery side
closed, the water in the pump may heat up
so that there is a risk of scalding yourself
with hot water.

The pump should not run against the 
closed delivery side for more than 
5 minutes. 

If liquid fails to flow, switch off the pump
immediately. 

Location 

Caution: Pursuant to DIN VDE 0100-702 and
0100-738 use of the pump nearby swimming
pools and garden ponds and other similar pla-
ces is only permissible if the pump is operated
via a residual-current device (FI switch) with a
residual current rating of 

30 mA. The pump

must be located on solid, even ground, protec-
ted from flooding. Take care that the pump
cannot fall into water. As an additional safety
device an authorised safety switch can be
used.

Please ask your electrician for his advice.

Extension cables

Date indicated on the type plate must match
technical data of the mains supply.

Pursuant to DIN VDE 0620, power cable as
well as extension cables must not have a
smaller diameter than rubber sheathed cables
described with letter symbols H07 RNF.

Don’t use the power cable for carrying the
pump or for plugging off.

2. For Your Safety

In Austria 

In Austria, the electrical connections must be
made according to ÖVE-EM 42, T2
(2000)/1979 § 22 based on § 2022. Pursuant to
this regulation it’s imperative to operate pumps
for swimming pools and garden ponds exclusi-
vely via an isolating transformer.

Please ask your electrician. 

In Switzerland

In Switzerland mobile appliances which are
used outdoors, must be connected via a resi-
dual-current device.

Visual check

Before operating the pump, first make a
visual cheek, if there is any damage of the
pump (esp. regarding power cable and
plug).

A damaged pump must not be used. 

In case of damage, please have the pump
checked by our GARDENA Service Centre
or by an authorised electrician. 

Note

Protect the pump from rain. Don’t use the
pump in wet or moist area

In order to avoid dry-running of the pump, take
care that the end of the suction hose is always
submerged into the liquid. 

Before each operation, fill the pump to
overflowing with approx. 2 to 3 l of the
liquid to be pumped!

Sand and other abrasive substances in the
liquid cause in-creased wear and reduce the
pump’s output.

Use a pump preliminary filter for pumping
sandy liquids. 

The minimum flow rate is 80 l / h (= 1.3 l / min). 
Watering accessories with lower rate must not
be operated.

Содержание 3000/300 Jet

Страница 1: ...e de surface pour arrosage NL Gebruiksaanwijzing Beregeningspomp S Bruksanvisning Bevattningspump I Istruzioni per l uso Pompa da giardino E Manual de instrucciones Bomba para jardín P Instruções de utilização Bomba de Jardim DK Brugsanvisning Trykpumpe 3000 3 Jet Art 1442 D GB F NL S I E P DK ...

Страница 2: ... for domestic use around the house and garden When using the pump for pressure intensification the max per missible internal pressure of 6 bar on the delivery side must not be exceeded The increased delivery pressure and the pump pressure have to be added together Example Pressure at the tap 1 5 bar maximum pressure of the Garden Pump 3000 3 Jet 3 3 bar total pressure 4 8 bar Liquids that can be p...

Страница 3: ... not have a smaller diameter than rubber sheathed cables described with letter symbols H07 RNF Don t use the power cable for carrying the pump or for plugging off 2 For Your Safety In Austria In Austria the electrical connections must be made according to ÖVE EM 42 T2 2000 1979 22 based on 2022 Pursuant to this regulation it s imperative to operate pumps for swimming pools and garden ponds exclusi...

Страница 4: ...itable for connecting 13 mm 1 2 16 mm 5 8 or 19 mm 3 4 hoses using the GARDENA hose connection system Best results regarding the delivery capacity of the pump are achie ved when connecting 19 mm 3 4 hoses in conjunction with e g GARDENA Pump Connection Set art no 1752 or when using 25 mm 1 hoses with fittings available from your sanitary dealer Connect the pressure hose to the connector on the del...

Страница 5: ... that no liquid can escape from the pump via the suction hose 5 Maintenance The GARDENA Garden Pump is essentially maintenance free Cleaning your Garden Pump The pump must be cleaned after pumping chlorinated swimming pool water 1 Rinse the Garden Pump with lukewarm water max 35 C If necessary add some soft cleaning agent e g washing up liquid 2 Remove residuals according to the waste disposal law...

Страница 6: ...d to be pumped over the filler cap before operation Suction filter at the suction hose is sucked free Suction filter or backflow preventer clogged Leaks at suction side Impeller blocked No power Thermal overload switch has cut out the pump due to overheating overloading Electric failure Remedy Fill the pump see 4 Operation 1 Fill the pump again see 4 Operation 2 When starting operation hold the pr...

Страница 7: ... Pump Preliminary Filter sandy liquids GARDENA Electronic Automatically cuts in and out the Art no 1739 Manometric Switch pump depending on the current operating pressure With dry running safety GARDENA Prevents the pump from damages Art no 1741 Dry Running Safety in case of missing liquid GARDENA For vacuum resistant connection of Art no 1729 Bore Hole Suction Hose the pump to boreholes or pipe n...

Страница 8: ...eeping with the requirements of the operating instructions Neither the purchaser or a non authorised third party have attempted to repair the unit The impeller is a wearing part and is not covered by the warranty This manufacturer s guarantee does not affect the user s existing warranty claims against the dealer seller If a fault occurs with your Garden Pump please return the faulty unit together ...

Страница 9: ...odukten om skadan beror på att produkten har reparerats felaktigt eller om vid repa ration eller utbyte andra än Original GARDENA reservdelar har använts Samma sak gäller för kompletteringsdelar och tillbehör Responsabilità Si rende espressamente noto che conformemente alla legislazione sulla del prodotto responsabilità del prodotto non si risponde di danni causati da nostri arti coli se originati...

Страница 10: ...midad de la UE El que subscribe GARDENA Kress Kastner GmbH Hans Lorenser Str 40 D 89079 Ulm declara que la presente mercancía objeto de la presente decla ración cumple con todas las normas de la UE en lo que a normas técnicas de homologación y de seguridad se refiere En caso de realizar cualquier modifi cación en la presente mercancía sin nuestra previa autorización esta declara ción pierde su val...

Страница 11: ... av 0 5 m med 25 mm 1 sugslang Le prestazioni indicate nella curva di rendimento presuppongono un altezza di aspirazione pari a 0 5 m e l impiego di un tubo da 25 mm 1 Los datos de rendimiento de la curva característica de la bomba se han medido con una altura de succión de 0 5 m y con una manguera de succión de 25 mm 1 A informação técnica com as características de performance acima descritas for...

Страница 12: ...8 Budapest Iceland Heimilistaeki hf Saetun 8 P O Box 5340 125 Reykjavik Republic of Ireland Michael McLoughlin Sons Hardware Limited Long Mile Road Dublin 12 Italy GARDENA Italia S p A Via Donizetti 22 20020 Lainate Mi Japan KAKUDAI Mfg Co Ltd 1 4 4 Itachibori Nishi ku Osaka 550 Luxembourg Magasins Jules Neuberg Grand Rue 30 Case Postale No 12 Luxembourg 2010 Netherlands GARDENA Nederland B V Post...

Отзывы: