EN
8
< 6 l/hr), the pump switches off completely. When the leakage on the
pressure side is eliminated, the pump must be unplugged and plugged in
again in order to be operational again.
Stop valve:
The integrated stop valve closes as soon as no more water is drawn.
Thermal protection switch:
In the event of an overload, the pump is switched off by the built-in
thermal motor protection. After sufficient cooling of the motor, the pump
is operational again.
4. STORAGE
To put into storage:
v
Store the pump away from frost before the first frost sets in.
Disposal:
(in accordance with RL2012/19/EC)
The product must not be disposed of to normal household waste.
It must be disposed of in line with local environmental regulations.
IMPORTANT!
v
Dispose of the product through or via your municipal recycling
collection centre.
5. MAINTENANCE
Clean inlet filter and suction foot [ Fig. M1 ]:
DANGER! Electric shock!
There is a risk of injury from electric shocks.
v
Before maintenance, disconnect the submersible pressure
pump from the mains.
1. Turn out the 8 screws
6
with a screwdriver.
2. Remove the suction foot
7
from the pump.
3. Remove the inlet filter
8
and the spacer ring
9
from the pump.
4. Clean the suction foot
7
, inlet filter
8
and the spacer ring
9
.
5. Place the spacer ring
9
onto the pump in such as way that tab
0
fits into the hole in the pump.
6. Put the inlet filter
8
onto the pump.
7. Put the suction foot
7
onto the pump and screw in the 8 screws
6
.
For safety reasons, a damaged turbine must only be replaced by
GARDENA Service.
6. TROUBLESHOOTING
DANGER! Electric shock!
Es besteht Verletzungsgefahr durch elektrischen Strom.
v
Vor dem Beheben von Störungen die TauchDruckpumpe vom
Netz trennen.
Problem
Possible Cause
Remedy
The pump does not deliver
any water
Air cannot escape as the
pressure line is closed.
v
Open pressure line (e. g. bent
pressure hose).
Air cushion in suction foot.
v
Unplug mains cable and plug
in again.
Inlet filter or suction foot
blocked.
v
Disconnect mains plug, clean
inlet filter and suction foot
(see 5. MAINTENANCE).
Pump overheated:
Thermal protection switch
switched pump off due to
overheating.
v
Disconnect mains plug, clean
inlet filter and suction foot
(see 5. MAINTENANCE).
Observe max. media tempera-
ture (35 °C).
Lack of water:
Dry run protection switched
the pump off due to
insufficient water level.
The pump is only operational
when it is submerged at least
12 cm.
v
Submerge pump at least
12 cm in water.
Problem
Possible Cause
Remedy
The pump does not deliver
any water
Leakage on the pressure side:
Flow control switched the
pump off (flow < 6 l/hr).
v
Check pressure hose and all
consumers on the pressure
side for tightness.
Unplug
pump and plug in again.
Power supply interrupted.
v
Check fuses and electrical
plug-in connections.
Stop valve jammed.
v
Flush outlet area with clear
water and free stop valve.
Delivery rate suddenly
decreases
Inlet filter or suction foot
blocked.
v
Disconnect mains plug,
clean inlet filter and suction
foot (see 5. MAINTENANCE).
Lack of water:
Dry run protection switched
the pump off due to
insufficient water level.
The pump is only operational
when it is submerged at least
12 cm.
v
Submerge pump at least
12 cm in water.
NOTE: For any other malfunctions please contact the GARDENA service depart-
ment. Repairs must only be done by GARDENA service departments or specialist
dealers approved by GARDENA.
7. TECHNICAL DATA
Submersible Pressure Pump Unit
Value (Art. 1476)
Rated Power
W
1050
Max. delivery capacity
l/h
6000
Max. pressure
(= switch-off pressure)
bar
4.5
Max. delivery height
m
45
Switch-on pressure
bar
2.6 ± 0.2
Max. submersion depth
m
12
Power cable
m
15 H07RN-F
Pump connection
mm
33.3 (G 1" female thread)
Minimum submersion depth
on commissioning
cm
12
Weight without cable
(approx.)
kg
8.0
Fastening rope
m / mm
15 length / ∅ 5
Max. media temperature
°C
35
Mains voltage /
Mains frequency
V / Hz
230 / 50
Sound power level L
WA
1)
dB(A)
46
Measuring process complying with:
1)
60335-1
8. ACCESSORIES
GARDENA 2- / 4-Way Valve
For parallel connection for more than one hose
or connected devices.
Art. 1210 / 1194
GARDENA Hose Clamp
For 25 mm (1" ) hoses via the connection nipple.
Art. 7192
GARDENA Hose Clamp
For 19 mm (³⁄₄" ) hoses via the connection nipple.
Art. 7191
GARDENA
Pump Connection Set
For 13 mm (¹⁄₂" ) hoses via the GARDENA
Connection System.
Art. 1750
GARDENA Tap Connector
GARDENA Hose Connector
For 16 mm (⁵⁄₈" ) hoses via the GARDENA
Connection System.
Art. 18202
Art. 18216
GARDENA
Pump Connection Set
For 19 mm (³⁄₄" ) hoses via the GARDENA
Connection System.
Art. 1752
9. SERVICE / WARRANTY
Service:
Please contact the address on the back page.
Warranty:
In the event of a warranty claim, no charge is levied to you for the services
provided.
GARDENA Manufacturing GmbH offers a two-year warranty (effective
as of the date of purchase) for this product. This warranty includes all
significant defects of the product that can be proved to be material or
manufacturing faults. This warranty is fulfilled by supplying a fully func-
Содержание 1476
Страница 3: ...3 I1 2 1 I2 2 I3 I4 I5 O1 5 4 3 O2 M1 0 9 8 7 6...
Страница 10: ...77...