removed thanks to the non-stick property of our products.
DO NOT SPRAY A CONCENTRATED WATER JET ON THE
PUMP.
This action will force water into the seals and damage the pump electronics. Let the hose run into the unit to
flush it. The pump will activate and send this fine debris to your garden. This fine debris will not be noticeable or harm
your garden in any way. Should you however not wish this debris to be used in the garden, switch off the power to
the unit and let the debris overflow to the sewer. This will take a few minutes but will flush your unit. To assist with
the cleaning process, you may put three to four cups of white vinegar into the water for an hour before flushing.
Vinegar is an excellent ecological friendly cleaning product that will help sterilise your unit and keep it in pristine
condition.
Garden ResQ also recommends that the general appearance and external components be cleaned on an as needed
basis to maximise the general appearance and life of the product.
Trouble Shooting:
Issue
Resolution
Water is not entering the GardenResQ unit
Check the plumbing into the unit. If a diverter valve is connected ensure
that is in the correct position to divert water into the unit. If it is and
water is not entering the unit, contact your plumber as it is likely that
you have a broken pipe.
Water is entering the unit, however the pump is
not operating.
Check that the power is on, and that the unit is plugged in. Check the
float switch and ensure it is clean and free from debris that may be
preventing it from operating effectively. On the Maxi, you may be
required to shorten the travel on the float switch. This is done by
reducing the float switch cable length travel by one or two centimetres
at the securing ties. DO NOT CUT THIS CABLE
The pump is working correctly, however a large
volume of water is exiting the unit via the return to
sewer outlet
Remove the sprayer/sprinkler connection to your irrigation and allow
the water flow freely from the unit or irrigation pipe. If the water flows
freely the irrigation pipe may contain blockages and should be checked.
Please also ensure that your filter is clean
Unit Technical Specifications
Pump *
Power consumption (Watts)
Approx Flow (l/min) @
30cm head
Shut Off Head Height
Garden ResQ MAXI
400
180
7.5m
Garden ResQ MAXI PRO
750/900
170
9.0m
Please remember that these heads exclude the irrigation pipe length. i.e water flow is reduced for every metre of 20