background image

 
 

 

www.gardenresq.co.za 

[email protected] 

 

When considering where to place your PYRAMID SPRINKLER in your garden,

 Garden ResQ recommends the following set backs are 

adhered to as these either meet or exceed most authority’s requirements. 
 

 

0.5 metres from closed fence boundaries 

 

0.5 metres from paths, driveways and carports  

 

1.2 metres from open boundaries  

 

1.0 metres from buildings  

 

6.0 metres from subsoil drains connected to storm water 

 

50 metres from bore holes intended for human consumption 

 

100 metres from potential public water supplies – dams, rivers etc 

 

100 metres from wetlands and other water dependant ecosystems 

 

 

System Operation: 
 

After  installation  of  both  the  unit  and  the  connection  of  your  irrigation  pipe,  you  unit  should  now  be  ready  for  fully  automated 
operation.  
 
To ensure all components have been installed and configured correctly please complete the following procedure; 
 

 

Turn the Garden ResQ unit  on

 

at the power point  

 

 

Ensure that all plumbing is securely connected in order to direct the flow of grey water into the unit 

 

 

Turn the water on in either the bath or shower once connected to the Garden ResQ device to enable a flow of water into 
the unit 

 

 

Observe the functioning of the float switch. The float switch will trigger the pump when it is above the horizontal position 
and before any water exits the overflow pipe. The pump is configured to continue operating until the float switch passes 
the horizontal position and hangs downward. The unit will deactivate when a predetermined amount of water still remains 
in  the  unit.  This  is  to  allow  for  very  hot  water  that  may  enter  the  unit  to  cool.  Hot  water  will  damage  the  pump,  float 
switch housing – and your garden 

 

 

Congratulations. If the unit operates as indicated above, you are now ready to fully automate the irrigation of your garden 
with grey water.  

 

 

This  unit  was  designed  for  use  with  a  subsurface  irrigation  system  or  the  ‘pyramid’  type  garden  sprayer.  Please  do  not 
connect this unit to a micro mist or pop-up type irrigation systems as you may damage the pump. Grey water WILL also 
block your micro mist sprayers – regardless of what you have been told. 

 
 

Maintenance: 
 

The Garden ResQ unit requires very little maintenance; however adherence to the following guidelines will ensure trouble free 
operation.  
 
The only maintainable component of the Garden ResQ unit is the filter, all other components do not require any maintenance.  
 
GardenResQ recommends the following maintenance regime; 
 

 

When  first  installed,  check  the  filter 

every  third  day  for  the  first  week

.  By  checking  the  filter  regularly  when  first 

installed you will soon be able to establish the level of debris that collects on the filter brush.  

 

 

Thereafter, the filter will need to be cleaned 

every 7-10 days.

 It can be cleaned by simply removing the filter brush 

from the basket and hosing it down. The basket debris may be disposed of in your rubbish bin. Please remember that 
additional  houseguests  will  increase  the  volume  of  water  through  the  unit  and  therefore  will  also  increase  the 
regularity of maintenance. 

 

 

In addition to the cleaning of the filters, you will notice a build up of general scale and soap scum on the inside of grey 
water sump, pump and on  the float switch. 

On a monthly basis,

 the sump area should  be cleaned with  your fresh 

water hose and an adjustable sprayer. By spraying a concentrated spay within the unit and sidewalls, all grime will be 

Содержание Grey Water

Страница 1: ... AREA SOME MUNICIPALITIES HAVE SPECIFIC MINIMUM SET BACK GUIDELINES FOR GREY WATER IRRIGATION PLEASE OBSERVE THESE QUIDELINES BELOW GREY WATER MUST NEVER BE STORED FOR LONGER THAN 24 HOURS THE GARDEN RESQ UNITS ARE DESIGNED TO EVACUATE ALL BUT APPROX 20 LITRES OF GREY WATER THIS IS NORMAL AND PREVENTS THE NEXT BATCH OF HOT WATER TO BE COOLED BEFORE IRRIGATING THE GARDEN Installation of the Garden ...

Страница 2: ... enter the unit to cool Hot water will damage the pump float switch housing and your garden Congratulations If the unit operates as indicated above you are now ready to fully automate the irrigation of your garden with grey water This unit was designed for use with a subsurface irrigation system or the pyramid type garden sprayer Please do not connect this unit to a micro mist or pop up type irrig...

Страница 3: ... valve is connected ensure that is in the correct position to divert water into the unit If it is and water is not entering the unit contact your plumber as it is likely that you have a broken pipe Water is entering the unit however the pump is not operating Check that the power is on and that the unit is plugged in Check the float switch and ensure it is clean and free from debris that may be pre...

Страница 4: ...apers Always wash your hands after gardening or handling the Garden ResQ grey water diversion unit Do not irrigate vegetable gardens supplying food crops that are eaten raw or undercooked as this could pose a health risk Never store grey water for longer than 24 hours Do not allow grey water to pool or stagnate as this will attract unwanted insects e g mosquitoes and rodents which can transmit dis...

Отзывы: