REQUIRED TOOLS:
9/16" SOCKET/OPEN-END WRENCH, 3/16" ALLEN WRENCH & #2 PHILLIPS-HEAD SCREWDRIVER
STEP 1: ATTACH SLIPFITTER (SF) TO TENON
NOTE: Tenon must be 3.75" length (min.) and 2-3/8"
diameter.
Remove splice cover from Slipfitter. Place slipfitter
over tenon and route supply wires from pole into
splice compartment. Using supplied (4x) 3/8"-16 set
screws w/nylok, tighten the slipfitter to tenon.
Torque bolts to 18 ft-lbs.
STEP 2: ATTACH LUMINAIRE TO SF
Install (1x) 3/8"-16 x 1" bolt, split washer and flat
washer to top threaded hole on slipfitter. Do not
tighten all the way, leaving approx. 1" gap to hang
luminaire. Loosen (2x) retained screws that secure
the door to the luminaire. Hinge door down to access
mounting holes in arm. Hang the luminaire using the
key slot feature, over the top bolt on the slipfitter.
Ensure that the washers remain on the inside of the
luminaire.
STEP 3: SECURE LUMINAIRE
Once Luminaire is hanging on slipfitter, insert the
remaining (1x) 3/8"-16 x 1" bolt, split washer and flat
washer into lower threaded hole on Slipfitter.
Torque
mounting hardware to 18 ft-lbs.
Feed the supply
wires from luminaire, through slipfitter mount and
into the splice compartment. Reinstall door to
luminaire using the (2x) retained #8-32 screws.
Torque door screws to
20 in-lbs.
STEP 4: MAKE WIRE CONNECTIONS
Once luminaire is installed and hardware is properly
torqued, make supply wiring connections inside the
splice compartment according to the appropriate
wiring diagram. Reinstall splice compartment cover.
* 0-10V AND OVERRIDE WIRES OPTIONAL
* WIRE NUTS SUPPLIED BY OTHERS
STEP 5: ADJUST / AIM PRODUCT
Loosen the 1/2"
–
13 socket cap bolt located in
slipfitter arm. Do NOT remove bolt. Loosen enough to
allow rotation on cast teeth. Using the degree
indicators, shown as a guide, rotate the luminaire to
the desired position and retighten the bolt to
47 ft.-lbs
.
NOTE: Product may be aimed up to +45° from
horizontal in 5° increments.