PP420 LED lighting controllers - User Manual
TT1
Enable the internal trigger and use the previously
set period
TT1,p
Enable the internal trigger and set the period.
Where:
p
= period of the trigger in milliseconds
For example:
TT1,200
Set the internal trigger to 200ms (5Hz)
TT1,500US
Set the internal trigger to 500μs (2kHz)
11.3
Command summary
Command
Example
Effect
AW
AW
Save changes.
ST
ST
Show configuration.
GT
GT1
Enable Ethernet messages.
GR
GR
Get any error codes.
CL
CL
Clear all settings except Ethernet.
EY
EY,65,66
Set webpage password to 'PW'.
VR
VR
Read the firmware version.
RE
RE1,3
Set channel 1 to ignore lighting errors and
not prompt for the current rating of a light
when it is connected.
RR
RR1,0.2
Set the rating of channel 1 to 0.2A.
RS
RS2,65
Set channel 2 to 65% brightness
continuous.
RW
RW1,50
Set channel 1 to 50%, switched by
trigger 1.
RT
RT2,3,4,50
Set channel 2 to 3ms pulses, delayed by
4ms, at 50% brightness.
RP
RP1,2
Use trigger input 3 for channel 2.
TR
TR2
Simulate a trigger on trigger input 2.
TT
TT1,1ms
Set internal triggers every 1ms.
—
33
—