25
10.1.2
Continuous Output Mode
In this case the mode of operation is selected and a single current output value
defined.
RS
Set the mode of operation
Syntax:
RS
f
S
m
Where:
f = output channel (1 or 2)
m = 0 for continuous current
RC
Set the output current for the selected channel
Syntax:
RC
f
C
c
V
v
E
e
Where:
f = output channel (1 or 2)
c = output selection (in this case 0)
v = output current (mA)
e = (optional) maximum current rating of the LEDs.
If it is not required, leave the Ee off the command.
Example of Continuous Output Mode
Set a continuous current of 0.5A on output channel 1
RS1S0
Select continuous current
RC1C0V500
Current = 500mA
10.1.3
Selected Continuous Output Mode
In this case the mode of operation is selected and a current output is defined for
each output required in the selected mode.
RS
Set the mode of operation
Syntax:
RS
f
S
m
Where:
f = output channel (1 or 2)
m = 4 for 2 currents selected using input 1
m = 5 for 2 currents selected using input 2
m = 6 for 4 currents selected using both inputs
RC
Set the current for the selected output channel.
Syntax:
Rc
f
C
c
V
v
E
e
Where:
f = output channel (1 or 2)